Interior and Exterior Finishes Flashcards
What type of fastener would typically be used to fasten drywall to metal framing?
Found in R702.3.5.1
a: Pan head screws
b: Bugle head type S screws
c: 8d commons
d: 10d commons
b: Bugle head type S screws
True or False. 1/2 inch gypsum material can be used for draft-stopping in construction where required.
Found in R302.12.1
True
The purpose of fire blocking is to
a: Support mounted fixtures
b: Provide added support for structural members
c: Cut-off concealed draft openings between stories
d: None of the above
c: Cut-off concealed draft openings between stories
Maximum spacing of framing members for 1/2 inch and 5/8 inch gypsum panels are designed for use on framing centers up to\
a: 16 inch
b: 19 inch
c: 24 inch
d: None of the above
c: 24 inch
Durock cement board could be used for
a: Floor underlayment
b: Countertops
c: Wall tile
d: All of the above
d: All of the above
Abuse resistant panels are engineered to provide increased resistance to
a: Indentations
b: Light reflection
c: Indentation
d: None of the above
a: Indentations
Green faced gypsum panels would be used to reduce resistance to
a: Cold
b: Mold
c: Abuse
d: All of the above
b: Mold
Firecode Type X gypsum board would be used best for
a: Installation of wall tile
b: Exterior use
c: Most fire-rated assemblies
d: None of the above
c: Most fire-rated assemblies
Cold-formed steel framing supporting gypsum panels shall not be less than____inches.
Found in R702.3.3
a: 1-3/4
b: 1-1/2
c: 1-1/4
d: 1-1/8
c: 1-1/4
For gypsum board ceilings, perimeter edges shall be blocked using wood members not less than _____nominal dimension material.
Found in R702.3.6
a: 3/4 inch OSB
b: 2 inch x 4 inch wood
c: 2 inch x 6 inch wood
d: All of the above
c: 2 inch x 6 inch wood
True or False. Water-resistant gypsum board shall not be used where there will be direct exposure to water.
Found in R702.3.7.1
True
True or False. Two ingredients for as quality plaster job are quality products and skilled craftspeople.
True
Durock cement board could be used for
a: Floor underlayment
b: Countertops
c: Wall tile
d: All of the above
d: All of the above
Installation of plaster and lath shall conform to ASTM ____and ASTM ____.
Found in Table 2511.1.1
a: C842, C843
b: C926, C1063
c: C842, C754
d: None of the above
b: C926, C1063
True or False. Gypsum board can be used as a backer for cement plaster.
Found in (2510.2.1)
False
Plastering with cement plaster shall not be less than____coats when applied over metal lath.
Found in - 2512.1
a: 1
b: 2
c: 3
d: 4
c: 3
The curing time between the first and second coat of cement plaster shall be a minimum of____hours.
Found in Table 2512.6
a: 48
b: 24
c: 12
d: None of the above
a: 48
Plaster not used within____hours from the start of initial mixing shall be discarded.
Found in ASTM C926
a: 1
b: 1 1/2
c: 2
d: 2 1/2
b: 1 1/2
True or False. Before any finished flooring is installed the subsurface should be properly prepared.
True
Concrete garage floors should have a minimum compressive strength of____psi if the weathering potential is severe.
Found in R402
a: 2000
b: 2500
c: 3500
d: None of the above
c: 3500
True or False. It is always best to use a curing compound over freshly finished concrete when the floor will require adhesives for finished floor products.
False
An underlayment could be any of the following.
a: Plywood
b: Hardboard
c: Cement board
d: All of the above
d: All of the above
Carpet is sold by the which method.
a: Square foot
b: Total area of the project
c: Square yard
d: None of the above
c: Square yard
When is a good time to grout a new tile surface?
a: As soon as possible
b: Within two hours
c: 24 hours
d: All of the above
c: 24 hours