Initial Ventilator Settings Flashcards
1
Q
Volume Ventilation
A
Rate 10-14/min Vt 6-10 ml/kg FIO2 30-60%(100% Emergency) PEEP 0-9 cmH2O Mode SIMV, AC
2
Q
Pressure Control
A
Insp Pressure 20 cmH2O(4-6 ml/kg)
Rate 12-14/min
PEEP >10 cmH2O
FIO2 <60 %
3
Q
ARDSnet
A
Rate 12-14/min
Vt 4-8 ml/kg
FIO2 <60%
PEEP >10cmH2O
4
Q
NIV
A
IPAP 10-12
EPAP 4-6
FIO2 minimal
5
Q
HFOV
A
Rate 4-8 Htz
Amplitude chest wall vibration
Ti 33%
Bias Flow 40L/min
6
Q
APRV
A
P-high plat+3
T-high 4.5-6 sec
P-low 0-3 cmH2O
T-low 0.5-0.8 sec