• Purpose of IC-IPE

A

◦ Ensure core and NCS does not exceed there safety limits during operation and design basis occurrences
◦ Help ESF mitigating an accident

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

•System design basis to prevent core damage and protect NCS integrity

A

Keep DNBR above 1.14
NCS pressure below 2735
Keep fuel rod linear power below 18 Kw/ft
Pervert fuel center line melt at 5080 degrees

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

• Componets of IC-IPE

A
◦	4 redundant channels
◦	NIS cabinet 
▪	2 source range
▪	2 intermediate range
▪	4 power range
◦	SSPS
▪	Two cabinets, Train A and B
◦	NCP Monitor cabinet
▪	voltage and frequency of the NCP's
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

• Power sources of IC-IPE

A

◦ Protection set 1 (Channel 1) 120 VAC EVKA
▪ Processes control channel 1 (PCS Cabinet 1)
• NIS channel 1
• SSPS Channel 1 Input bay (Trains A and B)
• Turbine trip relays channel 1
• 48 VDA and 15 VDA power supplies
• SSPS Train A Output cabinet
◦ Protection set 2 (Channel 2) 120 VAC EKVB
▪ All the above for channel 2 except for SSPS Train A
◦ Protection set 3 (Channel 3) 120 VAC EKVC
▪ All the above for channel 3 except SSPS Train A
◦ Protection set 4 (Channel 4) 120 VAC EKVD
▪ All of the above for channel 4 except SSPS Train A
▪ Powers SSPS Train B Output cabinet
◦ Loss of a power source (Loss of a channel)
▪ All the bistable for that channel go into there tripped position
▪ All control room stat lights feed by that bistable turn on (EXCEPT for NS → energize to illuminate)
▪ Logic will change from 2:4 to 1:3 or 2:3 to 1:2
▪ Should not cause a Rx trip

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

• System Alarms IC-IPE

A

◦ PCS 2/4 cabinet doors open
▪ Warns of possible trip by having work done in two cabinets at the same time. Will not cause general warning or trip. Warns operator.
◦ SSPS General Warning → reduction in protection by one of the following
▪ Loss of 48 VDC or 15 VDC power supply
▪ Printed circuit card not inserted properly
▪ Test switch in test
▪ Bypass breaker racked in and in connect
▪ Logic ground fuse blown
◦ First Out Alarm
▪ First alarm for a Rx trip will be red, subsequent alarms will be white
▪ Do not reset until a note has been made of what caused the trip

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

• Limits and precautions IC-IPE

A

◦ Rx trips on power range high flux (low set point) are unblocked when below interlock and permissive set point
▪ Power range low set point protection automatically reinstates.
◦ At power trips are automatically blocked (or unblocked) as nuclear power is decreased below (or increased above) the set points for the interlock P-7
▪ These trips include:
• Pressurizer high water level
• Pressurizer low pressure
• 2 loops loss of flow
• NCP bus under-voltage or under-frequency
▪ Protection automatically reinstates
◦ Control rod withdrawal is blocked (or unblocked) below 15% power as turbine load is decreased below (or increased above) set point C-5
▪ Plant systems are unstable below this point
◦ Only ½ decade left above P-6 when increasing power to block SR trip. Must do immediately upon receiving P-6
▪ Avoid a trip

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

REACTOR TRIP SETPOINT LOGIC PERMISSIVE BASES
MANUAL Sw. turned 45 1/2 sw. operator judgment

S.R. NI HIGH 105 CPS 1/2 ch. P6, P10 uncontrolled rod withdrawal/ startup accidents.

I.R. NI HIGH amps-25% power 1/2 ch. P10 uncontrolled rod withdrawal/ startup accidents

P.R. NI LOW 25% power 2/4 ch. P10 reactivity excursion from low powers

P.R. NI HIGH 109% power 2/4 ch. reactivity excursion from all powers DNB

P.R. POS RATE
	\+5%/2 sec	2/4 ch.		DNB (rod ejection)
PZR HIGH PRESS
	2385 psig	2/4 ch.		coolant system integrity
PZR LOW PRESS
	1945 psig	2/4 ch.	P7	DNB
PZR HIGH LEVEL
	92%	2/3 ch.	P7	water through safeties (system integrity)
OTT	T > OTTsp	2/4/ ch.		DNB

OPT T> OPTsp 2/4 ch. KW/FT

NCP BUS LOW VOLT
	74% of normal	2/4 ch.	P7	DNB (anticipatory loss of flow)
NCP BUS LOW FREQ
	56 Hz	2/4 ch.	P7	DNB (anticipatory loss of flow)
S/G LO-LO LVL	17% 	2/4 in
1/4 s/g		loss of heat sink
1 LOOP LOSS OF FLOW
	88%	2/3 in
1/4 loops	P8	DNB
2 LOOP LOSS OF FLOW
	88%	2/3 in
2/4 loops	P7	DNB
SAFETY INJECTION	any S/I signal actuated	1/2 S/I trains		trip reactor if trip not generated by trip instrumentation

GENERAL WARNING ALARM loose card, loss of voltage, train in test, by-pass bkr connected/closed, logic ground return fuse blown
2/2 alarms loss of protection
TURBINE TRIP low Auto-stop oil press

A

INTERLOCKS LOGIC FUNCTION
P-4 Train A or B Reactor Trip • Turbine Trip
• Feedwater Isolation 10-10 amps Allows manual block of S.R. Reactor Trip. De-energizes high voltage to the Source Range detectors. On decreasing power, Source Range Level trips are automatically reactivated and high voltage restored.
P-7 2/4 P.R. > 10% FP (P-10) or 1/2 impulse pressure> 10% (P-13) On increasing power P-7 automatically enables the following trips:
• Pzr High Level
• Pzr Low Pressure
• Low NC Flow 2/4 Loops
• NCP Undervoltage
• NCP Underfrequency
On decreasing power the above listed trips are automatically blocked.
P-8 2/4 P.R. > 48% FP On increasing power P-8 enables the 1/4 loop loss of flow Reactor Trip and Reactor Trip on Turbine Trip. On decreasing power, P-8 automatically blocks the above listed trip.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

INTERLOCKS LOGIC FUNCTION
P-10 2/4 P.R. > 10% FP On increasing power P-10 allows manual block of the Intermediate Range trip and rod stop (C-1). Allows block of the Power Range High Flux Low Setpoint trip and prevents the Source Range instruments from being Manually energized. (Will automatically de-energize both source range detectors if not previously de-energized at P-6.) Also provides an input to P-7. On decreasing power, the Intermediate Range trip and the Power Range trip are automatically reactivated, allows manual reset of SR High Voltage block if one IR channel does not decrease below P-6 to auto energize the SR circuit.
P-11 2/3 Pzr Press 10% Input to P-7
P-14 2/3 Level on 1/4 S/G Hi-Hi Level > 83% • Turbine Trip
• FWPT Trip
• Feedwater Isolation

A

INTERLOCKS LOGIC FUNCTION
C-1 1/2 I.R. > 20% FP Blocks automatic and manual rod withdrawal
C-2 1/4 P.R. > 103% FP Blocks automatic and manual rod withdrawal
C-3 2/4 OTT > OTT Stpt - 2% • Blocks automatic and manual rod withdrawal
• Actuates Turbine Runback @200% per minute 2.3 sec out of 30 sec.
C-4 2/4 OPDT > OPDT Stpt - 2% • Blocks automatic & manual withdrawal
• Actuates Turbine Runback @200% per minute 2.3 sec out of 30 sec.
C-5 1/1 Impulse Press 5%/min. or Step Decrease > 10%. Arms the condenser dump valves (Bank 1 & Bank 2) on a load rejection
C-9 Condenser Press 200 Steps Blocks automatic rod withdrawal

How well did you know this?
1
Not at all
2
3
4
5
Perfectly