Hydraulics Flashcards
Desired airspeed following any hydraulic system failure
75-100 kias
Tail Rotor Note
Note: with the 10-bladed tail rotor hub installed, the loss of a single hydraulic system (either by actual failure or by placing the TAIL HYD ISOLATE switch in CUTOFF) will result in considerable feedback in the pedals. Any isolate condition, including a #2 DC bus short, movement of the EECO to CUTOFF, or pulling the SEC HYD CB will also induce this condition
1) PRI SERVO P warning light illuminated
2) SERVO JAM warning light illuminated
3) Limit lights illuminated
4) HYD2 PRESS
Primary Hydraulic System Failure (pg 67-68)
1) Cruise airspeed - 75-100 kias
2) Avoid abrupt maneuvers
3) Land as soon as practicablef
1) SEC SERVO P warning light illuminated
2) SEC HYD LO PRESS warning light illuminated
3) SERVO JAM warning light illuminated
4) HYD1 PRESS
Secondary Hydraulic System Failure (pg 68-71)
1) Cruise airspeed - 75 to 100 kias
2) Avoid abrupt maneuvers
3) non-memory…
1) SEC HYD ISOLATE warning light illuminated
2) SERVO JAM warning light illuminated
Possible symptoms:
3) High-pitched noise from transmission area
4) Stiffness in flight controls
Secondary Hydraulic System Low Fluid Level (pg 72-77)
1) TAIL HYD ISOLATE switch - NORM
(Caution: if pedal pressure is not relaxed prior to placing the TAIL HYD isolate switch back to NORM, a rapid right yaw and pedal induced MGB overtorque may occur)
2) a lot of non-memory…
1) SEC HYD HI PRES warning light illuminated
2) SEC HYD LO PRES warning light illuminated
Secondary Hydraulic Pressure High/Low (pg 77-78)
1) Landing gear handle - down (check wheels down)
2) Safety pin - install (if available)
3) Monitor for indications of a secondary hydraulic system failure
4) Land as soon as practicable
1) SERVO JAM warning light illuminated
2) Flight control loading may increase
Servo Jam (pg 78)
1) SC JAM CB - pull, reset (pilot aft R5#8)
2) Land as soon as practicable
Any ONE of the following conditions:
1) HYD 1 pressure indication goes to full scale, zero, or is blanked
2) HYD 2 pressure indication goes to full scale, zero, or is blanked
3) PRI SERVO P warning light illuminated
4) SEC SERVO P warning light illuminated
Hydraulic Indicating System Failure (pg 79)
1) Monitor for secondary indications
2) Abort mission