Hvac Safety Checklist Flashcards
Refresher a d reminders of good safety practices
Section 2 unit 9
Transfer refrigerants only into ________ containers.
DOT-approved
Department of Transportation
Section 2 unit 9.
Why you should never overheat the system’s tubing while the system is pressurized
This can cause a blowout and serious injury.
When certain refrigerants are exposed to high temperatures, a flame, or a glowing hot metal, they can decompose into hydrochloric and/or hydrofluoric acids and phosgene gas.
Section 2 unit 9.
Why you should never energize the compressor when under a deep vacuum
This can cause a short in the motor windings at the fusite terminals or at a weak spot in the windings, which may damage the compressor.
What things should you look for in equipment and systems to help limit refrigerant
emissions?
EPA 608 Technician Certification Study Guide: Core 20
©2016 TPC Trainco SGEPA 101 0116
General Service & Maintenance
- making sure that equipment used is approved by the EPA,
- checking for leaks, repairing leaks
- making sure that all fittings are tight during service and recovery.
What is the most effective method for checking for small leaks
EPA 608 Technician Certification Study Guide: Core 20
©2016 TPC Trainco SGEPA 101 0116
General Service & Maintenance
When checking for small leaks, using a halide
torch is the most effective method
If the system completly lost its charge. How can you test a system for leaks
EPA 608 Technician Certification Study Guide: Core 20
©2016 TPC Trainco SGEPA 101 0116
General Service & Maintenance
If the system has completely lost its charge
and you want to test it for a leak, charge it with dry nitrogen for testing and never use refrigerant
gases.
Nitrogen is environmentally friendly and is safe to handle.
True or false
EPA 608 Technician Certification Study Guide: Core 20
©2016 TPC Trainco SGEPA 101 0116
General Service & Maintenance .
True
What should you do if a compressor burns out
EPA 608 Technician Certification Study Guide: Core 20
©2016 TPC Trainco SGEPA 101 0116
General Service & Maintenance
- Triple-evacuate the system.
- Install a permanent filter-drier.
- Conduct a deep vacuum before recharging
What will need to happen if the oil has been contaminated by a burnout?
EPA 608 Technician Certification Study Guide: Core 20
©2016 TPC Trainco SGEPA 101 0116
General Service & Maintenance
If you suspect a major leak or major component failure, an oil sample should be taken. If there
are contaminants in the oil, the system will need to be flushed.