General Quality Assurance Principles And Requirements For Liquid O2/N2 Production Flashcards
Physical Adsorption
Is where a layer of gas one or more molecules thick is attracted to a solid surface
Procurement Limits
Purity and contamination requirements for liquid and gaseous ABO whether it is generated by Navy and Marine Corps activities or procured from commercial sources
Use Limits
Use limits are applicable to storage tanks, servicing equipment and converters
MIL-PRF-27210
-covers the minimum DOD procurement limits and requirements for two types of ABO
Type I
Gaseous
Type II
Liquid
NSTM CH 550
-contains requirements, procedures and frequencies for the sampling and testing of Types I and II ABO
Sampling and testing of LOX
LOX should be taken as a liquid
Generating Plants shall be tested for acetylene during O2 and N2 production?
- within 4 hours after starting production
- every 24 hours thereafter
Acetylene testing and testing of trace contaminants on shipboard systems shall be drawn using?
FCS 2001
Odor Test shall be tested within?
4-8 hours after start of O2 or N2 production
How much sample should be poured into a clean 400-mil beaker?
200 mils
What is place on the bottom of the beaker?
Clean dry filter paper
What do partially cover the top of the beaker?
Watch glass
Testing requirements for storage tank for CO2
Type I-20.0 p/m
Type II-10.0 p/m
Testing requirements for storage tank Acetylene
Type I-0.2 p/m
Type II-0.1 p/m
Testing requirements for storage tank Refrigerants
Type I-4.0 p/m
Type II-2.0 p/m
Testing requirements for generating plants Acetylene
Type I-0.1 p/m
Type II-0.05 p/m
Testing requirements for generating plants CO2
Type I-10.0 p/m
Type II-5.0 p/m
Testing requirements for generating plants Refrigerants
Type I-2.0 p/m
Type II-1.0 p/m
Acetylene Storage Tank Particulate Test
- only required when contamination is suspected
- shall be no particles visible without the aid of magnification
Filling of non-ABO and ABO gaseous cylinders
Never allow the internal pressure go below 25 PSIG “WET cylinder”
FCS 2001 Cryogenic Sampler function?
Is used to receive, vaporize, collect and contain a sample of cryogenic liquid from a supply source
FCS 2001 charging manifold assembly components
- sample cup(inner)
- sample cup(outer)
- cooling inlet outlet port
- sampling inlet port
- heat transfer fins
- burst disk