General Operations Flashcards
What does closing C-402 suction valves with high motor amps mean.
C-402 is running to hard.
AIC-5010 pv ranges.
High = 3.25 Low = 2.5
While running, when should you run PIC-4010 in manual.
Near 10500 rpm.
Stream 1 on G.C
V-403 inlet.
Stream 2 on G.C
R-501 inlet.
Stream 3 on G.C
R-501 outlet.
What is AI-4002
S.G of incoming gas on V-403 inlet. Is also showen as a precent.
What is AI-4022
C-401 own gas analyzer. Located in the comp building. Runs in a 70% to 73% range.
What causes AIC-5010 to flunk to manual.
Bad pv
Bad G.C status
Pv changes by 0.1 in a single update.
No update within 600 seconds
What does high PDI-5005 mean.
Syn loop is getting heavy.
What are the black lines on the maintenance screen
Secondary line
What is the yellow line on the maintenance screen
Primary line
What direction is the wind the worst on a hot day.
West. It will blow warm air from the high line to E-509.
When would you start to shut HIC-4012.
Low rates. This can help out if Nova trips.
When would you expect V-506 to start gaining a level.
On hot days when C-402 is working hard. This will cause a C-402 trip.
When would you start to close HIC-4012.
When C-402 is working hard. Closeing HIC-4012 will temporarily slow the loop.
What can cause Nova’s compressors to overheat.
High pipeline pressure. Backing out of the loop quickly.
What is the max 02 in the feed
Our scale does not go past 5 ppm. At 50ppm back out of the loop.
How many starts from cold can C-402 take
2
How can you save steam while on recycle.
Set operator margin to 0.
Reset additional margin
How do you check to see suppresed alarms
Area Filter tag on delta V. Looks like German flag.
- When would you have FIC 4011 45% open?
2. Why would you do this?
- During start up.
2. Gives a buffer for your steam load. You can open or close this based on if you need less or more steam.
How can you steady the pressure in E-509.
You can shut a supply valve off to one side of E-509.
What do you do if you have lost all E-509 fans.
Feed prep trip.
Stream 4 on G.C
Purge gas stream.
How can you increase TIC-6045 temp.
Shut bottom dampers. You can starve the furnace for air. You will see a sharp spike in combustables.
If the temp is to high on TIC-6045 you can starve the furnace for air.
What loop speed works best to control the heat up of the Borsig.
20 to 25 m/s. This will slowly warm the Borsig and not cause a large swell.
On start up what does closing PIC-4005 do.
It will lower your H2 flow.
How can you help smooth out a transition to half rates or flat.
Set HIC-4012 to 60% set FIC-4011 to manual and open it while closing HIC-4012.
What does a higher then set point temp on TIC-6045 say about the super heater.
This tells you that you might be starving the super heater of air.
TIC-6041 PV will drop while the control will call for more heat.
What is one way to keep the steam system stable on start up
Hold gas back with FIC-4001 and pressure up Nova. This will keep the pressre off PIC-4010 so you dont have to speed up.
At what point do you know that HIC-4012 is open despite their being room to open futher.
You stop seeing an increase in loop velocity.
What is a surge event
When the margin decreases to less than 1%