Electric strikes used on fire rated opening must be
Fail secure
The ANSI/BHMA product standards would most likely be used in which type of specification
Reference
A drawing that illustrates where the electrified hardware products are located on and around an opening is referred to as an
Elevation diagram
Access control egress doors require which item on the egress side of the opening to ensure occupants can always exit a building or space.
A manual release device
Electric locks used on fire rated openings must be
Either fail safe or fail secure
Which of the following key set symbols indicates the third change key under the second master key in a level three GMK system
AB3 - Keying Systems and Nomenclature - Chapter 3 3-Level, Grand Master Key System Page 11
AA3 is example of:
A change key in a single grand master key system
Which type of wiring diagram is not typically required on a project?
System - AHC220 - AHC Exam Prep - Page 84 - There are three distinct types of wiring diagrams: Elevation, Riser, and Point-to-Point. Of these types, the elevation and point-to-point drawings will be needed on most projects. In some cases, combined Elevation/Riser diagrams are provided. You need to describe the type necessary for each of your projects. System diagrams are also becoming more prevalent as advanced systems are being provided. Remember to also require an operational description of how each opening will function once the electrical hardware is installed.
Electro-magnetic locks require what current to operate
DC
The primary purpose of specification is to:
Establish function, grade and quality - AHC220 - AHC Exam Prep - Page 81 - Writing the Specification - Before you begin to write your specification, you need to understand how the building is going to be used when it is occupied. You also need to determine the Owner’s preference for quality, design, function, and finish of the hardware.
Which of the following key symbols indicates a change key in a level 2 single master key system
2AA - Keying systems and Nomenclature- Chapter 2 - 2-Level, Master Key System - Page 9 - In a 2-Level master key system, the master key symbol consists of two letters (AA). The change number(s) come first.
Mounting heights push plates should be specified in which PART of a specification?
Part 3 Execution - AHC220 - AHC Exam Prep - Page 90 - Installation - Sentence 3 - Special instructions for the mounting locations of the various hardware items should be given - for example, push plate and pull or lock set lever heights.
Which of the following symbols indicates a cylinder keyed to a change key and grand master key only:
A1 - Keying systems and Nomenclature Chapter 3 3-Level, Grand Master Key System - Exceptions to Grand Master Key Systems: A1: Changes under the Grand Master Ley. if the cylinder is to be operated by its change key and nothing lower than the single lettered GMK, the change number is added to the GMK symbol. This is illustrated by the example A1 in the schematic shown. Cylinder operated by a change key and the Grand Master Key (omitting the master key). Use Grand Master key plus change number. Example: A1, A2, etc.
Which of the following specifications is used to specify a product by “what it is supposed to do and how well it does it”?
Descriptive
Which type of specification is written around the end result
Performance
Specifications for hinges are usually written using a combination of which specification method
Proprietary and descriptive