gas thermoelectric cut out device shut off times Flashcards
if a thermo electric shut off device fails to shut within allowed shut off time, should it be regarded as AR or ID
And why
ID
Immediately Dangerous
Because a safety shut off has failed
if a thermo electric shut off device fails to completely shut off gas but still shuts off within time allowed , should it be regarded as AR or ID
ID
Immediately Dangerous
Because a safety device has failed
what is the maximum shut off time allowed for a central heating boiler (upto 70kw net)
60 seconds
what is the maximum shut off time allowed for a cooker oven
60 seconds
what is the maximum shut off time allowed for a cooker hotplate or griddle
90 seconds
what is the maximum shut off time allowed for a space heater
manufactured before February 2000
180 seconds
what is the maximum shut off time allowed for a space heater
manufactured AFTER February 2000
60
what is the maximum shut off time allowed for warm air heaters
(upto 60kw gross)
60 seconds
what is the maximum shut off time allowed for a storage water heater
(less than 8kw gross)
90 seconds
what is the maximum shut off time allowed for a storage water heater
(less than 8kw gross)
90 seconds
what is the maximum shut off time allowed for a storage water heater
(less than 8kw gross)
90 seconds
what is the maximum shut off time allowed for combi and multi-point water heaters
60 seconds
control manufacturers state that all their controls should cut off gas to appliance within what time
60 seconds
control manufacturers state that all their controls should cut off gas to appliance within 60 seconds unless what states otherwise
Manufacturers Instructions
MI’s