Furnace Start Up Flashcards
Furnace must be wired electrically and ground according to what? In the absence of that you should use?
Canadian electrical code (CEC), or CSA C22.1
The blower motor should be checked for.
Shipping blocks or brackets removed, motor mount checked for tightness
3 ways to check for a gas leak
Test dial on gas meter
Commercial leak detector (soapy water solution)
Electronic leak detector
How to check gas leak with test dial
Turn off gas to all appliances minus the one you’re working on, go to gas meter, locate test dial mark where dial is, wait ten minutes see if it moved.
What do electronic leak detectors detect
Detects the mercaptin.
All venting systems are required to first follow
Appliance manufacturers installation instructions.
All venting must match the what?
The category of furnace it is intended
All metal vent and vent connectors must be
ULC approved and adhere to b149 gas code
Metal vent connector material must be installed so that there is no
Dips or sags with all joints fully inserted and locked together.
All plastic vent must be certified to
ULC S636 and must be clearly marked.
Excessive air leakage could cause what
A shortage of warm air in certain rooms
On new construction it is good practice to?
Inspect entire heating ventilation and air conditioning.
What do you match the heat anticipator to?
The amperage of the 24 volt control circuit.
How to set a single stage Manifold pressure
Must turn off gas at the gas cock first and connect the manometer to the outlet pressure port on the gas valve
Failure to set the air temp rise can result in?
Reduced furance life