Fuel Flashcards

1
Q

The respective L/R FUEL QTY annunciation illuminates when the associated nacelle quantity decreases to approximately ________.

A

Approximately 300 lbs, or less than 30 minutes of fuel remaining at max continuous power.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

The jet transfer pumps normally receive motive flow fuel from what source?

A

Engine-driven boost pump

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The CROSSFEED light illuminates when the __________.

A

CROSSFEED valve is in the open position

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

The _____-bus powers the fuel quantity gauges.

A

Triple fed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Maximum fuel imbalance is ______ pounds.

A

300

How well did you know this?
1
Not at all
2
3
4
5
Perfectly