FOAM HANDLINE/ADDENDUM 3 Flashcards
125 GPM FOAMD EDUCTOR issued to all..?
ENGINE /SQUADS
- pelican case
- adjustable fog/straight stream
- GO -GAUGE
- meters (1%-3%-6%)
- shall be used with UNIVERSAL GOLD–AR-AFFF
- RED BAND CONTAINER
GO GAUGE NEEDLE…
-2 positions/red or green
GREEN indicates proper foam proportioning
needle in RED indicates problem…such as…
- KINK
- BURST LENGTH
- nozzle not fully open
- nozzle shut
- ELEVATION problem
EDCUTOR is to be operated at PUMPER OUTLET ONLY..
-either 1 3/4” or 2 1/2”
stretches are NOT TO BE COMBINED
1 3/4”–6 lengths max
2 1/2’-10 Lengths max
When using a 2 1/2” hose , a 1 1/2” x 2 1/2” increase and a 2 1/2” by 1 1/2” reducer is required..
these fittings should be kept INSIDE the educator box (pelican case)
ECC will supply foam line with _____psi
200 psi/125 gpm
-nozzle maintained fully opened
Nozzle can operate with TIP in either SEATED or EXTENDED position..
seated —foam blanket produced
extended-aerated foam blanket produced
*aerated is longer lasting foam blanket and should only be used on HYDROCARBON fires WITH AN alcohol content
When the ECC notices the go gauge needle in the RED…
HE WILL FIND AND SOLVE PROBLEM (NOT OFFICER)
When foam ops are complete, NOZZLE shall be flushed out UNITL CLEAN WATER IS FLOWING
-at this time nozzle is SHUT DOWN, ECC Goes to idle , reduce pressure in outlet and THEN PRESS RED FLUSH BUTTON on EDUCTOR , this will flush educator and pick up tube….do this unit FRESH CLEAN WATER is flowing through pick up tube