Flt Deck Prep Flashcards
FDAS TEST: How is it checked? When does it need to be done?
FDAS Switch NORM. Door OPEN FLT DK Door switch AUTO access code + ENT -double chime -auto unlock illuminates FLT DK Door switch DENY -auto unlock light extinguishes FDAS switch OFF -lock fail illuminates FDAS switch NORM (Inside flight deck) Close door ensure locks FDAS - OFF
Only on the first flight
When do you have to address PBE with replacement before takeoff?
Both seals broken and pink spot.
(Broken seals and a baby girl)😳
Fault/inop detection test. What should you see during the test?
OVHT/DET switches - NORMAL TEST switch - FAULT INOP VERIFY (2) master cautions OVHT/DET Annunciator FAULT light APU DET INOP light
What happens if during the fire protection FAULT/INOP test you notice the FAULT light fails to illuminate?
The fault monitoring system has failed
What should you do if you notice during the fire protection FAULT/INOP test that the APU DET fails to illuminate?
DO NOT OPERATE THE APU
OVHT/FIRE detection test. What should you see or hear during the test?
Test switch - OVHT/FIRE Warning Bells (2) Master Warning Lights (2) Master caution lights OVHT/DET annunciator illuminate
Master Fire WARN - push
-verify bell and master fire cancel
-verify
—ENG1/APU/ENG2 fire illuminate
—ENG1 and ENG2 OVHT lights illuminate
A/C power - Main Wheel Well fire illuminate
Verify FAULT light and APU DET INOP stay extinguished
-if fault light illuminates a detection loop is inoperative.
CARGO FIRE/SMOKE detection test. What should you see or hear during the test?
Detector Select -Norm/both Test switch -push -verify Fire Bell (2)Master fire Warning PUSH Master Warning LIGHT -verify Fire bell ceases Master Warning lights extinguish Cargo Fire (FWD/AFT) warning and EXT are illuminated -verify Detector fault remains extinguished
Prior to APU start what should you confirm?
APU bleed switch -OFF PACK switches- OFF #1 AFT fuel pump- ON
What should you see when you turn on GEN #1 bus switch (apu running)?
Both Transfer Bus Off lights- extinguish
No. 1 Source off light - extinguish
What should you see when you turn on GEN #2 bus switch (apu running)?
No. 2 Source off light - extinguish
BAT Discharge Light- extinguish
Main wheel well fire warning test. What should you see or hear during the test?
TEST switch - hold to OVHT/FIRE Verify -fire bell -(2) master warnings -(2) master cautions -OVHT/DET annunciator illuminates PUSH MASTER WARNING Verify -Bell cancels -(2) Master Warning lights extinguish -Wheel Well Fire light illuminated
What should you hear when you press the mach airspeed warning?
Clacker
What should you see when stall warning is pushed?
Control column vibration
-The stall warning test requires AC transfer busses be powered for 4 mins.
When you connect AC POWER what lights should extinguish?
Transfer Bus Off, Source Off, Bat Discharge, TR Unit, ELEC, Standby power off lights ELEC Standby power off Source off Transfer bus off Unit TR Discharge (battery)
What is the verbatim announcement to Flight Attendants prior (minimum of 2 mins prior) to Takeoff?
Flight Attendants should now be seated for Takeoff