Flows Flashcards
1
Q
SIM Left Seat
A
- Yaw Damper - ON
- Fuel Pumps - Main tanks (all 4) ON, center tanks as RQD
- Seat Belt Sign - ON
- Window Heat - ON
- Hydraulic Pumps - A’s OFF / B’s ON
6 Autobrake - RTO - T/O Warning Horn -Check
- Aileron/Rudder Trim - Centered
2
Q
Push Back
A
- Pushback Time - Noted
- Anti-Collision Light - ON
- ISOLATION VALVE - Confirm AUTO
- Recirculation Fan(s) - AUTO
- Air Conditioning - PACKS OFF
3
Q
CA - “Start #2”
A
FO - “Starting #2”
- Engine Start Switch 2 - GND
After rollback - Clock
- Engine Start Switch 2 - CONT
- ISOLATION VALVE - CLOSE
- R PACK - Auto/High
4
Q
CA “Start #1”
A
FO “Start Engine #1”
- Engine Start Switch 1 - GND
After Rollback - Clock
- Engine Strat Switch - CONT
4.- Ignition Switch - IGN L
- Engine Strat Switch - CONT
- APU Bleed - OFF (as required)
- L PACK - Auto/High
- ISOLATION VALVE - AUTO
5
Q
After Start Flow
Ground Crew and Equipment are Clear
A
- Electrical (GEN 1, GEN 2) - ON
- APU Switch - OFF
- PROBE HEAT Switches - ON
- Anti-ice - If required
- System A Hydraulic Pumps - ON
- PACK and BLEED Switches - As Required
- WHEEL WELL (Light) - OFF
- Oil Quantity - Check
- Start Levers - Verify IDLE detent
- Hand on Flap Lever - “Standing by Flaps”