FIRE PROTECTION SYSTEMS Flashcards

1
Q

In what area of an aircraft would you find a carbon monoxide detector?

A

cockpit and/or cabin

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What occurs when a visual smoke detector is activated?

A

a lamp within the indicator illuminates automatically

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The types of fire-extinguishing agents for aircraft interior fires are

A

water, carbon dioxide, dry chemical and halogenated hydrocarbons

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

When air samples contain carbon monoxide, portable carbon monoxide detectors containing yellow silica gel will turn which color?

A

green

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Smoke detection instruments are classified by their method of

A

detection

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Smoke detectors which use a measurement of light transmissibility in the air are called

A

photoelectrical devices

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

A contaminated carbon monoxide portable test unit would be returned to service by

A

installing a new indicating element

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Which fire-detection system measures temperature rise compared to a reference temperature?

A

thermocouple

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

A carbon dioxide (CO(2)) hand-held fire extinguisher may be used on an electrical fire if the

A

horn is nonmetallic

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

The proper fire-extinguishing agent to use on an aircraft brake fire is

A

dry powder chemical

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Smoke in the cargo and/or baggage compartment of an aircraft is commonly detected by which instrument?

A

photoelectric cell

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Light refraction smoke detectors are activated when the detector

A

senses light reflected from smoke particles passing through a chamber

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Why does the Fenwal fire-detection system use spot detectors wired parallel between two separate circuits?

A

a short may exist in either circuit without causing a false fire warning

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

A fire-extinguisher container can be checked to determine its charge by

A

weighing the container and its contents

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What is the color code for fire-extinguisher lines?

A

brown

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

The most common cause of false fire warnings in continuous-loop fire-detection systems is

A

dent kinks or crushed sensor sections

17
Q

A thermocouple in a fire-detection system causes the warning system to operate because

A

it generates a small current when heated

18
Q

The thermocouple fire-warning system is activated by a

A

rate of temperature rise

19
Q

When used in fire-detection systems having a single indicator light, thermal switches are wired in

A

parallel with each other and in series with the light

20
Q

Built-in aircraft fire-extinguishing systems are ordinarily charged with

A

halogenated hydrocarbons and nitrogen

21
Q

In reference to aircraft fire-extinguishing systems,
(1) during removal or installation, the terminals of discharge cartridges should be grounded or shorted.
(2) before connecting cartridge terminals to the electrical system, the system should be checked with a
voltmeter to see that no voltage exists at the terminal connections.
Regarding the above statements,

A

both no. 1 and no. 2 are true

22
Q

What method is used to detect the thermal discharge of a built-in fire-extinguisher system?

A

a rupture of the red plastic disk in the thermal discharge line

23
Q

The thermal switches of a bimetallic thermal-switch type fire-detection (single-loop) system are heat- sensitive units that complete circuits at a certain temperature. They are connected in

A

parallel with each other, but in series with the indicator lights

24
Q

On a periodic check of fire-extinguisher containers, the pressure was not between minimum and maximum limits. What procedure should be followed?

A

replace the extinguisher container

25
Q

In some fire-extinguishing systems, evidence that the system has been intentionally discharged is indicated by the absence of

A

yellow disk on the side of the fuselage

26
Q

If a fire extinguisher cartridge is removed from a discharge valve, it should be

A

used only on the original discharge valve assembly

27
Q

Which of the following are fire precautions which must be observed when working on an oxygen
system?
1. Display ‘No Smoking’ placards.
2. Provide adequate fire-fighting equipment.
3. Keep all tools and oxygen servicing equipment free from oil or grease.
4. Avoid checking aircraft radio or electrical systems.

A

1,2,3,4

28
Q

Which fire-extinguishing agent is considered to be the least toxic?

A

. bromotriflouromethane (Halon 1301)

29
Q

Maintenance of fire-detection systems includes the

A

replacement of damaged sensing elements

30
Q

(Refer to Figure 21.) Using the chart, determine the temperature range for a fire-extinguishing agent
storage container with a pressure of 330 PSIG. (Consider 330 PSIG for both minimum and maximum
pressure.)

A

45 to 75 degree F