Which of the following areas have fire detection and extinguishing systems?
Engines, APU, Lavatories, Cargo Compartments
Engine overheat and fire detection is powered by the _________.
Battery bus
If one engine overheat and fire detection loop fails with the OVHT DET switch in normal _____________.
the failed loop is automatically deactivated and the remaining loop functions as a single loop detector
With the OVHT DET switch in normal, what does an illuminated amber FAULT light on the overheat fire protection panel indicate?
both detector loops for an engine have failed
With the OVHT DET switch selected to A, what does an illuminated amber FAULT light on the overheat fire protection panel indicate?
the A detector loop for an engine has failed
If both MASTER CAUTION lights, the OVHT/DET system annunciator light, and the related ENG OVERHEAT light illuminate, what has occurred?
An engine overheat
What are the indications of an engine fire?
() all answers are correct
() The fire warning bell sounds, both master FIRE WARNING lights illuminate, the related engine fire warning switch illuminates
() All related engine overheat alert indications illuminate
How are the engine fire warning switches unlocked?
Illumination of an engine fire warning switch, illumination of an ENG OVERHEAT light, or manually by pushing the fire warning switch override
Pulling the engine fire warning switch up ___________.
closes both the engine fuel shutoff valve at the HMU and the spar fuel shutoff valve
- closes the engine bleed air valve
- closes the hydraulic fluid shutoff valve and deactivates the engine driven hydraulic pump LOW PRESSURE light
Pushing the Fire Warning BELL CUTOUT Switch, extinguishes both master FIRE WARN lights, silences the fire warning bell and ___________.
resets system for additional warnings
During the Extinguisher test, positioning the EXT TEST Switch to 1 or 2 verifies circuit continuity from the squib to __________.
both engines and APU fire switches
Placing the Fault/Inoperative (FAULT/INOP) and Overheat/Fire (OVHT/FIRE) TEST Switch to the FAULT/INOP position __________.
tests the fault detection circuits for both engines and the APU
Placing the Fault/Inoperative (FAULT/INOP) and Overheat/Fire (OVHT/FIRE) TEST Switch to the OVHT/FIRE position __________.
tests overheat and fire detection loops on both engines and APU, and wheel well fire detector
An illuminated APU Fire Warning Switch, in the down position, indicates a fire in the APU, and _________.
unlocks the APU fire warning switch
During a number 1 engine overheat, which lights will illuminate?
ENG 1 OVERHEAT, MASTER CAUTION, and OVHT/DET system announciator