Fire Protection Flashcards
Fire warning BELL CUTOUT switch push does?
extinguishes both master FIRE WARM lights
silences the fire warning bell
silences the remote APU fire warning horn in wheel well
resets the system for additional warnings
Overheat Detector OVHT DET switch
Normal
A
B
normal both loop A and B are active
A loop is active
B loop is active
Extinguisher EXT test switch
it test bottle discharge circuit continuity for all three bottles.
Lights are green system is Normal
FAULT/INOP test what?
fault detection circuits for both engine and APU
OVHT/FIRE test?
overheat and fire detection loops on engines and APU
Each engine contains TWO overheat/fire detector loops
Engine fire Detection is powered by?
Engine fire Extinguishing is powered by?
Battery bus
Hot battery bus
ENG overheat light amber
indicates overheat in related engine
Note: master caution and OVHT/DET system annunciator lights illuminate.
Fault light amber
Normal both loops have failed
in A or B the selected loop has failed
Note: Master caution and OVHT/DET system annunciator lights do NOT illuminate
APU fire warning light ( in wheel well )
red flashing?
red steady?
indicates fire in APU
APU fire warning horn cutout switch has been pushed
Lavatory fire extinguisher
Temperature Indicator
White?
Black?
normal condition
exposed to high temperatures
Heat activated nozzles
Flat black?
Aluminum?
normal conditions
indicates extinguisher has discharged
both nozzles discharge toward the towel disposal container.
How many engine fire bottles?
2
Pulling the engine fire switch UP?
Closes Fuel Closes Bleed air Closes HYD Trips Gen disables thrust allows the engine fire switch to rotate arms one of the squibs on each engine fire extinguisher bottle
APU Fire Detection powered by
APU fire extinguishing powered by
battery bus
hot battery bus
How many Fire detection loops are on the APU
One