FIRE PANEL Flashcards

1
Q

Where are the engine fire loops installed?

A

a. Pylon nacelle
b. Engine core
c. Fan section

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What happens if both fire loops fail?

A

If the failure of both loops occurs within 5 seconds of each other, a FIRE warning will be issued.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What does an amber DISCH light mean?

A

The fire extinguisher bottle has lost its pressure.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

How many fire extinguishers are provided for each engine?

A

2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

List the actions that occur when an ENGINE FIRE push button is pressed.

A

a. 2 – Silences the aural fire warning and arms the fire extinguisher squibs
b. 1 – Closes the hydraulic fire shut off valve
c. 2 - Closes the low-pressure fuel valve and the IDG fuel return valve
d. 1 – Deactivates the IDG (FADEC power supply also deactivated)
e. 2 - Closes the pack flow control and engine bleed valves

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What occurs when you press the TEST push button on the ENGINE FIRE panel?

A

a. 7 lights
b. CRC sounds
c. MASTER WARN lights flash (2)
d. ENG FIRE pb illuminates red (1)
e. SQUIB and DISCH lights illuminate (2)
f. ECAM FIRE WARNING (1)
g. FIRE light on the ENG panel illuminates (1)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

How many fire extinguishers are provided for the APU?

A

1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

List the actions that occur when the APU FIRE push button is pressed.

A

a. 2 – Silences the aural fire warning and arms the APU fire extinguisher squib
b. 1 – Shuts down the APU (ECB)
c. 2 - Closes the low-pressure fuel valve and shuts OFF the APU fuel pump
d. 1 – Deactivates the APU generator
e. 2 - Closes the APU bleed and X bleed valves

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What occurs when you press the APU FIRE TEST push button?

A

a. CRC sounds
b. 5 Lights:
c. MASTER WARN lights flash (2)
d. APU FIRE pb illuminates red (1)
e. SQUIB and DISCH lights illuminate (1)
f. ECAM FIRE WARNING (1)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Does the APU fire extinguisher automatically discharge if a fire is detected on the ground?

A

Yes. The APU will automatically shut down and the APU fire extinguisher will discharge

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Does the APU fire extinguisher automatically discharge if a fire is detected in flight?

A

No

How well did you know this?
1
Not at all
2
3
4
5
Perfectly