Additional signals that are received on the annunciator panel in the fire control room is a strong indicator of what?

A

Advancing fire

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
1
Q

A report of nothing showing needs to be what?

A

Aggressively investigated

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

When a working fire in a high-rise building is confirmed command officers should also consider requesting what?

A

RIT 2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The operational plan for a high-rise fire consist of five basic points what are they?

A

Determine fire floor

Verify fire floor

Control occupants

Control of building systems

Confine and extinguish the fire

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

In what ways can you confirm or determine the fire floor on a high-rise fire?

A

Information on dispatch

Information from building occupants

Smoke or fire showing from the structure

Checking the annunciator panel or fire control room indicators

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

At a minimum what building systems must be brought under fire department control at a high-rise fire?

A

Elevators

Fire pump

HVAC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Exposure protection not only involves checking the floor above but also requires companies to be assigned to check where?

A

Check areas extremely remote from the fire floor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Engine companies should not open doors into the fire area until what information is relayed to them?

A

What the wind conditions are

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

When can personnel choose to stretch free connected winds from the engine on a high-rise fire?

A

When the fire is located on the first or second floor or below grade

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Whenever the stretch will be made from the apparatus and not the standpipe what must happen?

A

It must be communicated to other units

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What must happen even if the initial attack is made with Handlines stretch directly from the apparatus?

A

That the standpipe system is still supplied

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

The fire loading in residential occupancies in a high-rise building is considered what?

A

Low

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Officers should give strong consideration of what an advanced fires and upper floors in a residential high-rise?

A

The use of a 2 1/2 inch line

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

The fire load and commercial occupancies in a high-rise is considered what?

A

Moderate

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What will determine whether the standpipe connection is made on the fire floor or on the floor below the fire?

A

Conditions and locations of the fire

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

If a vehicle fire is located in a attached garage of a high-rise how should crews treat this call?

A

As a high-rise fire