Final test Flashcards
What is a water Service
From water main to building or structure
Plastic pipe cones in what types
Schedule 40 and 80
What is a gate valve
Either on or off
Globe valve
Can be throttled to control flow. Has arrow that points down stream
What is Check valve
Permits flow in one direction
prevents backflow
Pressure reducing valve
Reduces or increases pressure
What is a union
Dielectric “prevents corrosion of similar metals
What is cathodic protection
Impressed currents, rectified AC to DC
Graphite, iron, zinc
Separation of pipe distance
Parallel 5’
Crossing 12”
Can plastic pipes pass through fire rated walls
No
What shoukd pipes in mech rooms have
Sleeves
Blwhere are blow out toilets used
Health-care facilities
ADA stand for
American disabilities act
Another name for urinals
DFU
Drainage fixture unit
Most common type of urinal
Wash out type
Which type of urinal has removable cartridge
Waterless
Right-hand/left-hand regarding bathtubs means what
Drain as you face it
Left hand drain on left
When inspecting fixtures what’s one thing to look for
Fixtures should operate quietly
Sanitary system purpose
Removes domestic waste excluding raw / surface water
Transfers from source to treatment plant
Below ground sewer slope
1/4” per 1’
Baterboards spacing for below ground sewer
25’-50’
Rotary pumps are classified by what
4 types
The type of rotating element it has
Screw
Gear
Love
Veneal
Where are reciprocating pumps used
Used where precise amount of liquid is on other end required to be delivered and where delivery pressure is higher
3 types of reciprocating pumps
Piston
Plunger
Diaphragm
Most common sewage pump
Centrifugal
Plastic / PVC pipe weighs how much less than metal pipe
One half to one sixth the weight
What is a circuit in plumbing
Group of fixtures that connects back to main vent
Max amount of fixtures that can connect to a horizontal branch drain
8
What is the purpose of an interceptor
Installed in sanitary drain system to trap or intercept
Grease / sand
Air test is for how long
5psi for 15 mins
Auto fire detectors must conform to what
Applicable provisions of NFPA 72
Auto fire detector must be arranged how
To alert building occupants and transmit signal to constantly attended location
Must not rely on any other system
Must be stand alone
Ionization types of smoke detectors
Dual chamber design
Indicator lamp
Correct voltage / current
For Auto sprinklers you must check for what
Loose or bent deflectors or bent frames
Auto sprinklers solder must withstand what temp
50° above normal room temp