FFP HRFMDs & LRFPMDs Flashcards

1
Q

FFP MDs , 6.1 note

A priority when performing building inspection in a HRFPMD should be to verify what?

A

verify that stairways are correctly labeled.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

FFPMDs 6.1.2 A

Like high rise office building procedures, ventilation of the fire apartment in HRFPMDs should take place When?

A

after the main body of fire has been controlled.

The IC shall control all ventilation other than the fire apartment.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

FFP MDs 6.1.3.C

Can The doors to elevator machinery rooms at the roof level be used for ventilation purposes?

A

The doors to elevator machinery rooms at the roof level should not be used for ventilation purposes UNTIL the fire is under control.
After the fire is under control, the elevator machinery room, if located at roof level, can be vented by opening doors to the exterior, as long as wind will not force smoke back into the building.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

FFP MDs 6.1.3..H
At a HRFMD, After all units are in position, and two elevators are available and serviceable, Where should the two elevators be positioned?

A

One elevator on standby in the lobby and one TWO floors below the fire.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

FFP MDs 6.1.4 A
When the main body of fire in a HRFPMD has been
controlled on the fire floor, adjoining apartments can be forced for reasons such as?

A

high carbon monoxide readings or severe smoke conditions in the public hallway.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

FFP MDs 6.1.4. B
Generally, In HRFPMDs the only apartment requiring access on the floor above
is the apartment directly above the fire apartment. No other doors should be forced without sufficient reasons,like?

A
  • high carbon monoxide readings at the end of a hall,
  • specific reports of persons needing assistance,
  • concentrated smoke conditions due to stack
    effect on a particular floor.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

FFP MDs 6.1.7

The FAST Unit and CFR Engine shall be assigned to the Fire Sector when the fire is ABOVE the_______floor.

A

6th floor
At lower floor fires ( 6th floor or below) the position of the FAST Unit and the CFR Engine will be determined by the IC.
The FAST Unit should carry a set of elevator keys.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

FFP MDs 6.2.1. B & 6.3.1 (1)
Your the 1st due Eng boss and You and the 1st due Lad officer just selected the attack stairway for a fire in a HRFPMD. Who Makes the notification (eng or lad boss) and Who do you have to notify?

A

The 1 st due Engine officer Notifies the 2nd engine and IC of the designation of the attack stairway.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

FFP MDs 6.2.2 A

What is the Equipment the 2nd due Eng. at a HRFPMD Should bring?

A
  • One length of 2½” hose per firefighter
  • Standpipe kit
  • Post Radio (obtained from first arriving Battalion)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

FFP MDs 6.2.3 C

When Charging the 2nd line in a HRFPMD The 1st due Eng. officer & control FF should be notified, why?

A

When the 2nd line is charged the pressure on the first line may drop; therefore, the control firefighter and officer of the first line should be notified.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

CM ch.2 , 2.12.3.
Your assigned 4th due eng. to a 10-77 fire in a HRFPMD
What letter will Your units designation be?

A

“N” for HRN

ie; E69N

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

FFP MDs 6.2.5.A

CFR Engine Company will report to the IC and stand by with the FAST Unit. What equipment should the CFR-d Co. have?

A

♦ CFR equipment

♦ Forcible Entry Tools

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

FFP MDs 6.3.1.C

What is 1st due Roof FF tool Assignment in a HRFPMD?

A

Halligan
Hydra Ram
KO curtain

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

FFP MDs 6.3.1 D 1c
at a HRFPMD, If no outside operations, WCD or LSR evolutions are indicated, The 1st due chauf will team-up with 2nd chauffeur and proceed to roof.
What are other duties of the 1st due chauff?

A

Check the condition of the hallway on the top floor, and all stairways leading to the roof for the presence of smoke and victims. Notify the IC and ladder company officer of conditions found and search results.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

FFP MDs 6.3.2

If a WCD deployment in a HRFPMD is initiated who Must Coordinate this evolution?

A

The 2nd due Ladder officer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

FFP MDs 6.3.2 C

What are 2nd due Roof FF tools?

A

Halligan
Maul
LSR and Lifebelt

17
Q

FFP MDs 7.3.1

1st arriving Ladder @ a LRFPMD should proceed to the fire floor and notify the IC of what?.

A

if the stairs are open or enclosed.

18
Q

FFP MDs 7.3.1

At a LRFPMD,When there are two stairways, Who shalll notify the this info about the stairs and who gets notified?

A

1st arriving Ladder notifies the IC and the engine officer of the attack stairway.
Also notify the IC and eng. officer of the heat and smoke conditions found in the stairs or public hallways.

19
Q

FFP MDs 7.3.1 C

At LRFPMDs Roof Access will be obtained using the following priority order?

A
  1. Stairway in an attached adjoining building.
    In an individual building with two separate sections protected by fire doors, the use of a protected adjoining section is the priority. In this situation, these doors must be checked on the fire floor and the floors above to ensure
    that they are in the closed position.
  2. An enclosed evacuation stairway.
  3. Aerial Ladder or Tower Ladder.
20
Q

FFP MDs 7.5
CIDS INFORMATION
CIDS should be utilized for LRFPMDs to indicate?

A
  • Roof access.
  • The number and type of stairways or sections. Indicate if stairways are open or enclosed and if sections are protected by fire doors.
  • Apparatus access.
  • Hydrant locations as needed.
  • Search rope required (when necessary)
  • 1¾” hose, when approved for use in selected buildings