FEUX DE PSC STRUCTURE, MOYENS DE PREV / PARTICULARITES Flashcards
1
Q
ORDRES GENERAL QUI MERITENT D ETRE PRIS EN COMPTE
A
- STABIILITE AU FEU DE LA DALLE 30 A 1H30 VOIR 4 H POUR IGH
- PSC QUI DISPOSE DE MOYEN DE SECOURS TYPES COLONNES SECHES OU SPRINKLER
- PSC DE + DE 1 NIVEAU MOYEN DE DESENFUMAGE MECANIQUE AVEC COMMANDE AU NIVEAU DE LA RAMPE
- LA COUPURE DE L ALIM GENERALEDOIT RESTER EXEPTIONNELLE AFIN DE NE PAS METTRE A L ARRET LE SYSTEME DE DESENFUMAGE
2
Q
PARTICULARITES DES FEUX DE PSC
CERTAINS ELELMENTS PEUVENT FAVORISER UN DEVELOPPEMENT RAPIDE DU FEU.
LES SECOURS PEUVENT ETRE CONFRONTES A
A
- PROPAGATION HORIZONTALE RAPIDE
- PROPAG VERTICALE PAR LES JOINTS DE DIL ET LES GAINES
- PROPAG DESCENDANTE PAR LES ECOULEMENTS D HYDROCARBURE AU TRAVERS DE DALLE FISSUREES OU DESTRUCTUREES
- RISQUE D ENVAHISSEMENT PAR LES FUMEES DES NIVEAUX SUP
- PRESENCE D EVENTUELLES VICTIMES DANS LES ETAGES SUP
- DUFFERENTS TYPES DE MOTORISATION DES VL ( essence gasoil GPL gnv électriques hydrogène)
3
Q
6 ELEMENTS PRIMORDIAUX
A
- PRISE EN COMPTE DES MOYENS DE SECOURS DU PSC
- RECONNAISSANCES APPRONFONDIES DANS LE PSC ET LE BATIMENT
- LOCALISATION RAPIDE DU FOYER
- ATTAQUE MASSIVE DU FOYER
- UTILISATION DU DESENFUMAGE MECANIQUE
- UTILISATION DE LA MOUSSE QUI PEUT S AVERER JUDICIEUSE DANS CERTAINS CAS, niveau le plus bas attaque classique impossible ( demande du GMV)