1 FEUX D HABITATION LOCAUX DE PETIT VOLUME Flashcards
CARACTERISTIQUES
- GAZ ELECTRICITE
- PROPAGATION HORIZONTALE : * AUTRES CELLULES
* APPARTEMENT VOISIN - PROPAGATION VERTICALE
PORTES QUI DONNENT DIRECEMENT DANS L ESCALIER - POUR LES PERSONNES : RISQUE DE NE PAS POUVOIR EVACUER L APPART
: TENTATION DE SE REFUGIER SUR LES TOITS, BALCON, CORNICHES
EXTINCTION
CONDUITE AVEC LE SOUCI DE LE MAINTENIR DANS SON VOLUME INITIALE
- EN EVITANT DE POUSSER LE FEU PAR UNE ACTION NON COORDONNEE DES LANCES
- EN COUPANT LES PROPAGATIONS
LOCAUX DE PETIT VOLUME
LOCAUX EXIGUS NE COMPORTANT QU UNE SEULE PIECE ET NE DISPOSANT QUE D UN SEUL ACCES, POURVU OU NON D’UNE OUVERTURE SUR L EXTERIEUR
OU TROUVE T ON LES LOCAUX DE PETIT VOLUME
GENERALEMENT AU NIVEAU SUPERIEUR DES IMMEUBLES; DESSERVIS PAR UN ESCALIER DE SERVICE.
CHEMINEMENTS ETROITS COMPLEXE ET DE GDE LONGUEUR.
UN MEME NIVEAU PEUT COMPORTER UN GD NOMBRE DE LOCAUX
1ERE PRIORITE EN ARRIVANT POUR FEU DE LOCAUX PETITS VOLUME
REPERER RAPIDEMENT LE BON ESCALIER QUI MENE DIRECTEMENT AU NIVEAU SINISTRE
AU COURS DE L EXTINCTION IL CONVIENT DE
- SE RENSEIGNER SUR L OCCUPATION DE L ETAGE CONCERNE
- ENGAGEMENT DU PERSONNEL STRICTEMENT NECESSAIRE AVEC UN LANCE 500 L/MIN ET UN CHEMIN DE REPLI
- NE PAS STATIONNER DANS LES CIRCULATIONS, RISQUE DE PHENOMENE THERMIQUE
- RECHERCHE RAPIDE DE CREATION D UN SORTANT ET METTRE LA VO
- S APPUYER SUR L EXISTENCE DE PLAN
- ATTENTION A L OUVERTURE DES PORTES POUR NE PAS CREER DE MODIFICTATION AERAULIQUE BRUTALE
- LORS DES RECO DE LOCAUX REFERMER LES PORTES
ATTAQUE COMMENCEE, RISQUE PHENOMENES THERMIQUE ECARTES…
INVESTIR RAPIDEMMENT LES LOCAUX, RECO EN TOITURE, COURETTES ET LES PUITS DE LUMIERE