Feed Controllers Flashcards

1
Q

Measures HCL flow through PCV-200/270 to MTK-695.

A

F200/270

HCl vent to MTK-695

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Regulates HCl feed flow to reactor.

A

F201 A/B/C

Oxy HCl flow controller

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Regulates F201 A/B/C to control the total sum of HCl feed F201 A/B/C and HAPF Unit HCL F514

A

F201 A/B/C-S

Oxy Total HCl Flow Controller

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Regulates main ethylene flow to reactor. Normally set in ratio to HCl feed flow, to maintain feed stoichiometry, and control excess ethylene in recycle gas.

A

F202 A/B/C

Oxy Main Ethylene Flow Controller

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Regulates trim ethylene flow. Normally a fixed flow approx 500 scfm to give main feed valve room to control.

A

F203 A/B/C

Oxy Trim Ethylene Flow Controller

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Regulates main O2 feed to reactor. Normally set in ratio to HCl flow to maintain feed stoichiometry and control excess O2 in recycle gas.

A

F204 A/B/C

Oxy Main O2 Flow Controller

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Regulates O2 trim feed flow to reactor. Usually with a set flow of 300 scfms to give main feed valve room to operate.

A

F205 A/B/C

Oxy O2 Trim Flow Controller

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Regulates recycle gas flow to reactor. Normally runs 10,000-15,000 scfm to control superficial velocity depending on rates.

A

F206 A/B/C

Oxy Recycle Gas Flow Controller

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Regulates H2 flow to hydrogenator.

A

F207/F280

Hydrogen Flow Controller

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Regulates purge nitrogen flow during recycle gas compressor trip. Normally throttled in field to approx 1600 scfm.

A

F209 A/B/C

Purge Nitrogen for grid plate and associated equipment protection.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Prevents over pressure of HCl header, by venting to MTK-695.

A

P200/270

HCl header pressure controller.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Regulates Oxy HCl feed pressure approx 85 psi to aid in accurate feed flow.

A

P201/P275

Oxy HCl feed pressure controller

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Regulates ethylene feed pressure, approx 85 psi to in accurate feed flow.

A

P202/P220

Oxy ethylene feed pressure controller

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Indicates recycle gas comp discharge pressure.

A

P204 A/B/C

Oxy O2 feed pressure controller

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Indicates Oxy H2 feed pressure

A

P207/280

MRE-201/202 Feed H2 pressure transmitter

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Indicates Oxy HCl supply temperature.

A

T200

HCL header temperature transmitter

17
Q

Indicates HCl feed temperature after leaving hydrogenator.

A

T201/T277

Reactor HCl feed temperature transmitter

18
Q

Regulates ethylene feed temperature by adjusting steam flow to preheater. Temperature is set to prevent dew point corrosion and aid in accurate feed flow reading.

A

T202/T220

Oxy Ethylene Feed Temperature Controller

19
Q

Regulates O2 feed temperature at approx 156 C. Temperature is set to prevent dew point corrosion and aid in accurate feed flow reading.

A

T203/T230

Oxy O2 Feed Temperature Controller

20
Q

Indicates recycle gas compressor discharge temperature.

A

T204 A/B/C

RG comp discharge TT

21
Q

Regulates recycle gas feed temperature to approx 177 C.

A

T205 A/B/C

Oxy recycle gas temperature controller

22
Q

Indicates Oxy MRE-203/204 H2 feed temperature.

A

T206

MRE-201 H2 feed TT

23
Q

Indicates Oxy H2 feed pressure.

A

P207/P280

MRE-201/202 H2 feed PT

24
Q

Indicates Oxy HCl supply temperature.

A

T200

HCl supply TT

25
Regulates HCl feed temperature to prevent dew point corrosion and aid in acetylene conversion.
T207/T275 Reactor HCl feed temperature controller
26
Regulates ethylene feed temperature by adjusting steam flow to preheater. Temperature is set to prevent dew point corrosion and aid in accurate feed flow reading.
T202/T220 Oxy ethylene feed temperature controller
27
Regulates hydrogenator MRE-201 HCL feed temperature.
T207 Hydrogenator MRE-201 feed temperature controller
28
Indicates hydrogenator bed temperature in MRE-201.
T208 MRE-201 TT
29
Regulates hydrogenator MRE-202 HCl feed temperature.
T275 Hydrogenator MRE-202 feed temperature controller
30
Indicates hydrogenator MRE-202 bed temperature.
T276 MRE-202 temperature transmitter
31
Indicates Oxy MRE-205 H2 feed temperature.
T280 MRE-202 H2 feed TT