Choose the answer that is most correct based on Chapter 10, Hydrants:
1. The primary agent used by this department to extinguish fires is water. Which of the following is incorrect regarding water sources?
a) The primary source of water for firefighting operations is hydrants.
b) Engine companies carry water in booster tanks.
c) Engine companies are capable of drafting water from lakes and reservoirs.
d) Engine companies are not permitted to draft salt water.
Chapter 10, Hydrants
1. D
2. Which of the following hydrants has a black barrel with a silver bonnet, contains two outlets, one 2 1⁄2” and one 4 1⁄2” and also is equipped with two valves, a main and a drain which are activated by the operating nut on top of the hydrant? A) Smith Low Pressure Hydrant B) Dresser Low Pressure Hydrant C) Chapman Hydrant D) Eddy Hydrant E) High Pressure Hydrant
Chapter 10, Hydrants
2. A
3. Which of the following hydrants provides 10-15% greater water discharge? A) Smith Low Pressure Hydrant B) Dresser Low Pressure Hydrant C) Chapman Hydrant D) Eddy Hydrant E) High Pressure Hydrant
Chapter 10, Hydrants
- B
- Which 2 of the following were originally installed by private water companies, may have two 2 1/2” outlets and opens and closes in a direction opposite other hydrants in NYC?
a) Smith Low Pressure Hydrant
b) Dresser Low Pressure
c) Chapman Hydrant
d) Eddy Hydrant
e) High Pressure Hydrant
Chapter 10, Hydrants
4. C,D
- Which of the following hydrants are being removed, out of service, and if encountered not to be used?
a) Smith Low Pressure Hydrant
b) Dresser Low Pressure
c) Chapman Hydrant
d) Eddy Hydrant
e) High Pressure Hydrant
Chapter 10, Hydrants
5. E
- Which of the following is considered incorrect regarding hydrants in New York City?
A) The number on the barrel of the hydrant indicates the depth of the main supplying the hydrant.
B) The number on the barrel of the hydrant indicates the size of the main supplying the hydrant.
C) A white line under the number on the barrel indicates the hydrant is on a dead end main and is only supplied from one direction.
D) Dead end mains are generally smaller in diameter and provide less water than mains fed from two directions.
Chapter 10, Hydrants
6. A
7. Which of the following is not equipment an Engine Company uses in connecting to a hydrant? A) 25’ soft connection B) 35’ soft connection C) 10’ small connection D)10’ hard suction E) 50’ length of 3 1⁄2” hose
Chapter 10, Hydrants
7. A
8. Which of the following hydrant connections must be used for drafting? A) 25’ soft connection B) 35’ soft connection C) 10’ small connection D)10’ hard suction E) 50’ length of 3 1⁄2” hose
Chapter 10, Hydrants
8. D
9. Which of the following is the newest connection available to the Engine Company Chauffeur? It is yellow, 5” hose carried in a trough on the front bumper extension andprovides the largest flows of any of the hydrant connections. A) 25’ soft connection B) 35’ soft connection C) 10’ small connection D)10’ hard suction E) 50’ length of 3 1⁄2” hose
Chapter 10, Hydrants
9. B
10. Which connection is 4 1⁄2” hose with 3 1⁄2” butts, requires close and accurate positioning at the hydrant and is carried on the side of the apparatus in a horizontal tray? A) 25’ soft connection B) 35’ soft connection C) 10’ small connection D)10’ hard suction E) 50’ length of 3 1⁄2” hose
Chapter 10, Hydrants
10. C
11. Which hydrant connection permits the most flexible in apparatus positioning but the least water flow? A) 25’ soft connection B) 35’ soft connection C) 10’ small connection D)10’ hard suction E) 50’ length of 3 1⁄2” hose
Chapter 10, Hydrants
11. E
BLANK
BLANK
- Which of the following is incorrect regarding hydrant security devices?
a) A hydra shield is a threaded hydrant cap with three indentations on both the 2 1⁄2” and 4 1⁄2” outlets.
b) The hydra shield wrench fits both the 2 1⁄2” and 4 1⁄2” outlet
c) A custodian hydrant guard is a free spinning cap which completely covers the hydrant operating nut to prevent it from being used by unauthorized users.
d) A custodian hydrant wrench is equipped with an internal magnet.
e) Under no circumstances shall a custodian hydrant wrench be struck with an axe, maul or similar tool.
f) A hydra shield wrench and a custodian wrench must both be taken to a hydrant with these security devices. One is used on the operating nut, the other to open the outlets with the hydra shield caps.
Chapter 10, Hydrants
- F