Where are the Ops Specs for Tempus Jets located?
The company Ops Specs are located in chapter 8 of the GOM. Part A--page 248 Part B--page 303 Part C--page 347 Part D--page 384 Part E--page406
A041 is authorization to conduct a Pre-takeoff Contamination Check.
Procedures are described in the GOM, chapter 5, appendix B.
A061 is authorization to use Electronic Flight Bag.
This is authorization to use class 1 hardware in accordance with GOM, chapter 4 procedures. iPad must be charged greater than 75% battery charge.
B035 is authorization to operate in Class A airspace using Area Navigation
This also includes authorization to fly domestic Q-routes. This DOES NOT include Q-routes in the Gulf of Mexico.
C052 authorizes Approach and Landing Minima.
TDZ RVR reports are controlling for all approaches to that runway. The mid RVR may be substituted for TDZ RVR if TDZ RVR is not available.
C055 authorizes Alternate Airport WX Minimums.
- 1 nav facility on the airport — + 400 and 1 mile.
- 2 nav facilites on the airport – + 200 and 1/2 mile.
• MUST NOT use alternate airport WX minimums that are N/A.
C064 authorizes Terminal Area IFR Ops in Class G Airspace without operating Control Tower.
This authorization requires: • Airport has SIAP • Approved WX source • Means to acquire traffic advisories • Facilities to conduct IFR operations.
D095 authorizes use of MEL.
Tempus Jets is authorized to use an FAA approved MEL. • Cat A--remarks column • Cat B--3 days • Cat C--10 days • Cat D--120 days
What are High Mins Captain Requirements?
Less than 100 hours PIC in type requires:
- add 1/2sm to visibility
- add 100ft to DA/MDA
- not to exceed applicable alternate landing mins for the approach being flown.
What are the IFR Fuel Requirements?
Fly to and land at the planned destination, + fly to and land at the alternate, + 45 min at normal cruise.
• Does not apply if IAP and alternate WX is not required.