Evolution 34 KO Cutain Deployment Flashcards
How many % decrease in temperatures when the KO curtain is deployed?
1.1
Testing conducted by the FDNY and NIST showed an immediate 50% decrease in temperatures and significant flame reduction when the KO Curtain is deployed. However, there will be an increase in the smoke condition produced by the fire.
What 2 people can order the KO curtain to be deployed?
1.2 Note:
The KO Curtain will ONLY be deployed on orders of the Officer of the first arriving ladder company and/or the Incident Commander.
The firefighters assigned to the floor above will be in a position to provide an accurate description of the effect the wind may have when the door to the fire apartment is opened. These firefighters SOP shall be?
3.2.1
-Force entry to the apartment above the fire.
-Chock open the entrance door to the apartment above.
-Survey and size-up the layout of the apartment above and communicate this information to the officers in the fire apartment.
-Check for any fire venting from the fire apartment and auto-exposing the apartment above.
-A pressurized water extinguisher may be required at the place of deployment in the case of auto exposure. A handline may be required for severe auto exposure.
-If auto exposure is not a problem, open the apartment window in the room over the fire room. Evaluate the wind condition and relay this information to the officers on the fire floor and the IC.
-Prepare the KO Curtain for deployment, and remove any window gates, child guards, blinds, curtains or other obstructions.
-Do not remove or break the deployment window unless absolutely necessary. An intact window will provide protection from auto-exposure, which may
occur due to shifting or gusty winds, allowing fire to intermittently vent from the fire apartment. Once the KO Curtain is deployed, members can expect
that fire will vent from the target window and auto expose the deployment window via the space between the KO Curtain and the building wall.
What are the deployment FF’s Tools and duties?
4.1 Deployment Firefighter
Tools: KO Curtain, Hydra-ram, Halligan.
Duties: Deploy the KO Curtain from a window in the apartment on the floor above, two floors above, or if the fire is on the top floor, then from the roof.
What are the receiving FF’s Tools and duties?
4.2 Receiving Firefighter
Tools: Hydra-ram, Halligan, Halligan hook.
Duties: Positioned below the target window, in the apartment below the fire apartment.
Secure the lower ropes of the KO Curtain and coordinate positioning over the target window.
Why should the deployment FF have their full PPE and facepiece donned when deploying the KO curtain?
5.2
The Deployment firefighter must have their facepiece on and full PPE donned when deploying the KO Curtain. This will protect the Deployment firefighter from unexpected auto-exposure which will subject them to fire, smoke and superheated gases.
Should the KO Curtain be deployed from the horizontal or vertical position?
5.4
Remove the KO Curtain from the case, place on the floor below the Deployment Window. The KO Curtain shall NEVER be deployed in the horizontal position. The KO Curtain is designed and shall be deployed ONLY in the vertical position.
When the KO Curtain is in position and ready to be deployed who gets notified and will coordinate the deployment?
5.7
Estimate how much rope will span from the Deployment Window sill to the top of the Target Window. When the receiving and deploying firefighters are in position and ready, notify the ladder company officer that the KO Curtain is position and ready to be deployed. The 1st arriving ladder company officer on the fire floor will coordinate the deployment.
How is the KO Curtain deployed from the window (is it thrown or dropped)?
5.8
When deploying the KO Curtain, the firefighter shall grasp the ropes, place and hold the KO Curtain outside the open window. Press the hand holding the ropes under the sill and lock the ropes with hand against the wall. Allow the KO Curtain to drop (do not throw) and cover the Target Window. Receiving member will gather KO Curtain ropes at Receiving Window.
If the KO Curtain will be subject to direct flame exposure for an extended period of time, the IC should consider what action?
5.12 Deploying a second KO Curtain or Fire Window Blanket to cover the first one.
Once the fire has been extinguished, it may be necessary to remove the KO Curtain to
assist in ventilation of the fire apartment. The removal of the K.O. Curtain must be approved by the Incident Commander. What Officer makes that request after conferring with who and what actions need to be taken prior to it being removed?
5.14
The request for removal of the KO Curtain will be made by the Ladder Company Officer inside the fire apartment, after first consulting with the Engine Company Officer in charge of the hoseline inside the apartment. The Ladder Company Officer shall use the Thermal Imaging Camera to confirm all fire has been extinguished. The Engine Officer shall insure that the nozzle team is aware of KO Curtain removal, and is prepared to extinguish any increase in fire conditions resulting from removing the KO Curtain.