Evolution 32 Implementation of Emergency LSR procedures Flashcards
Who and why is the Emergency LSR evolution implemented?
- 1 This evolution will only be implemented under the direction of a Command Chief. Activation will be transmitted via signal 65-2 by voice alarm, Department radio, ATSP and MDT. This evolution will be implemented on a citywide basis when a large number of personal harnesses and/or personal safety systems have been placed out-of-service and immediate replacement is not available. The intention of this procedure is to provide a measure of safety to members operating without personal harnesses and/or personal safety
systems. It will remain in effect until further orders. When the equipment has been replaced and all on-duty members have been properly equipped, the Command Chief will rescind the implementation of this evolution.
How many stories does a NFP bldg. have to be for the 1st and 2nd due Roof FF’s to bring their LSR’s?
What type of Fireproof Bldg.’s do they need to bring their LSR’s?
- 1 Members assigned the Roof position in the first and second ladder companies at structure fires involving non-fireproof buildings that are 3 stories in height or greater shall bring their Life Saving Rope to the roof of the building. Additionally, members assigned the Roof position in the first and second Ladder companies at fireproof residential-type structures including apartment houses, nursing homes, senior citizen housing, dormitories,
etc. , shall bring the Life Saving Rope to their position on the floor above.
What shall the 1st due roof FF do after arriving at their position with the LSR?
2.2 The 1st Roof firefighter shall carry the Life Saving Rope to their position and then perform assigned duties on arrival at the roof level (or floor above in fireproof residential buildings).
What are the duties of the 2nd due roof FF after arriving at their position during the implementation of this evolution?
The 2nd Roof firefighter shall carry the Life Saving Rope to their position. Immediately after reaching their position, identify possible substantial objects for use in tying off the Life Saving Rope and position the Life Saving Rope at that location for possible use. This member will also position the Life Saving Rope of the first ladder company at a
substantial object, using a different one if available. This action will readily identify the location of a designated substantial object for Life Saving Rope deployment. After completing this initial duty, the 2nd Roof firefighter shall then perform assigned
duties at the roof level (or floor above in fireproof residential buildings), remaining alert to any condition that might require immediate use.
when should the Rope be removed from the carrying case?
NOTE: The Life Saving Rope shall not be removed from the carrying case except for actual rescue and removal operations.
When are the Roof FF’s allowed to leave the Roof?
2.4 These two Roof firefighters shall maintain their position at the roof level (or floor above in fireproof residential buildings) until the Incident Commander declares the operation “Probably Will Hold,” or the Incident Commander informs the members to either evacuate the roof or that their services on the roof are no longer required.
Both Roof FF’s shall monitor their Handie-talkies for what?
2.5 Both Roof firefighters shall monitor the handie-talkie for deteriorating conditions that might require deployment of the Life Saving Rope, such as an interrupted or delayed application of water on the fire. This may require one or both members to move to a location remote from operating saws or other ambient noise.
What is the preferred method of removal of distressed members wearing a personal harness?
2.6 The preferred method for removal of distressed members wearing a personal harness is for them to remove themselves from danger via a single slide utilizing a Life Saving Rope that has been deployed from above.
What is the preferred method of removal of distressed members not wearing a personal harness?
2.7 The preferred method for removal of distressed members not wearing a personal harness from danger is for the two roof members to perform Evolution 25, 26 or 27 to remove the distressed member from danger.
What are the 4 actions a distressed member should take?
- DISTRESSED MEMBER ACTIONS
A. Transmit a MAYDAY on the handie-talkie when realizing possible need.
B. Identify Unit and position.
C. Specify location for rope deployment.
D. While awaiting the LSR from above, fully clear the window of all obstructions.
When using a vertical object as a substantial object where is the optimum spot for the rope to be tied off?
5.1 The substantial object must be carefully selected. There are many objects of questionable
integrity that should never be used; e.g., soil pipe vents, TV antenna masts, etc. Any chimney or other object chosen should be quickly examined for soundness and any sharp edges. When using a vertical object, such as a chimney or dumbwaiter bulkhead, allow the rope to drop to the base, close to the roof. The object should be at optimum strength at this point.