Equipment Cooling Panel Flashcards
What are the two switches on the equipment cooling panel?
Supply and exhaust
What are the switch positions ?
NORM and ALTN
What does it mean when the supply/exhaust switch is in both Norm and ALTN position?
NORM:
- Normal cooling supply fan activated
- Normal cooling exhaust fan activated
ALTN:
- ALTN cooling supply fan activated
- ALTN cooling exhaust fan activated
What does the equip cooling supply/exhaust OFF light illuminated mean?
When illuminated Amber, no airflow from selected cooling supply fan or exhaust fan.
What does the equipment cooling system do?
It cools the electronic equipment in the flight deck and the E&E bay.
To which part of the aircraft does the supply duct supply cool air?
Flight deck displays
Electronic equipment in the E&E bay
What is the purpose of the exhaust duct?
It collects and discards warm air from:
- the flight deck displays
- overhead and aft electronic panels
- circuit breaker panels in the flight deck
- electronic equipment in the E&E bay
When will the equipment cooling exhaust fan be shut off and the equipment cooling exhaust fan light OFF be inhibited?
In the event of a forward cargo fire warning
What happens if an over temperature occurs on the ground ?
Alerting is provided through the crew call horn in the nose wheel well