EPH Flashcards
Analyses for Leaded Gasoline/Aviation Gasoline
Soil/Sed - VO+TIC, 1,2-dibromoethane, 1,2-dichloroethane, lead
Water - Same
Analyses for Unleaded Gasoline
Soil/Sed - VO+TIC, Tert butyl alcohol
Water - Same
Analyses for Light Petro Distillates (Naptha, Stoddard Solvent, Paint Thinner, etc)
Soil/Sed - VO+TIC
Water - Same
Analyses for Kerosene, Jet Fuel
Soil/Sed - VO+TIC, Naphthalene, 2-Methylnaphthalene
Water - VO+TIC, SVOC+TIC
Analyses for No 2 Heating Oil and Diesel
Soil/Sed - EPH, 25% of samples where EPH > 1,000 mg/kg for Nap/2MN
Water - VOC+TIC, SVOC+TIC
Analyses for No. 4 and 6 Heating Oil, Hydraulic Oil, Cutting Oil, Lubricating Oil
Soil/Sed - EPH, 25% samples where EPH>100 mg/kg for PAHs
Water - VOC+TIC, SVOC+TIC
Analyses for Crude Oil
Soil/Sed - EPH, VOC+TICs, SVOC+TICs, TAL Metals
Water - VOC+TICs, SVOC+TICS, TAL Metals, Ammonia (total)
Analyses for Waste Oil or Unknown Petroleum Hydrocarbons
Soil/Sed - EPH, 25% samples with EPH detections for VOC+TICs, SVOC+TICs, PCBs, TAL Metals
Water - VOC+TICs, SVOC+TICs, TAL Metals
Analyses for Waste Vehicular Crankcase Oil
Soil/Sed - EPH, 25% samples with EPH detections for VOC+TICs, SVOC+TICs, PCBs, Lead
Water - VOC+TICs, SVOC+TICs, Lead
Analyses for Mineral Oil
Soil/Sed - EPH
Water - EPH
Analyses for Dielectric Fluid, Dielectric Mineral Oil, Transformer Oil
Soil/Sed - EPH and PCBs, 25% of samples with EPH detections for PAHs
Water - EPH and PCBs
Analyses for MGP Sites
Soil/Sed - EPH, VOC+TICs, PAH, TAL Metals, Cyanide, Phenolics
Water - EPH, VOC+TICs, PAH, TAL Metals, Ammonia (total), Cyanide, Phenolics
What is the EPH Category 1 Product Limit?
8,000 mg/kg
What are the two product limits for EPH Category 2?
8,000 mg/kg for crude oil, LNAPL at MGP sites, unknown hydrocarbons
17,000 mg/kg for all other Category 2
What petroleum products are considered Category 1?
No 2 Heating Oil and Diesel Fuel