LOCA -Safety Functions

RCS Inventory

A

Condition 1

a. Pressurizer level greater than 10% [15%].
b. RCS is 24°F [44°F] or more subcooled.
c. RVLMS indicates that RVUH level is 16% or more.

Condition 2

a. Safety Injection flow is adequate. REFER TO Appendix 2, Figures.
b. CET Subcooling indicates less than 44°F [60°F] superheat and NOT rising.
c. RCS Subcooling indicates less than 44°F [60°F] superheat and NOT rising.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

LOCA-Safety functions

RCS Pressure Control

A
ACCEPTANCE CRITERIA: 
Condition 1 
a. Pressurizer pressure within the P/T limits. REFER TO Appendix 2, Figures. 
Condition 2 
a. Safety Injection flow is adequate. 
REFER TO Appendix 2, Figures.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

LOCA- SAFETY FUNCTION

  1. Core Heat Removal
A

a. CET Subcooling indicates less than 44°F [60°F] superheat and NOT rising.
b. RCS Subcooling indicates less than 44°F [60°F] superheat and NOT rising.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

LOCA- Safety Functions

  1. RCS Heat Removal
A

a. At least one Steam Generator has level 45 - 60% [45 - 60%] NR.
OR
Feedwater is restoring at least one Steam Generator level to 45 - 60% [45 - 60%] NR.

b. Tc is stable or lowering.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

LOCA- Safety Functions

  1. Containment Isolation
A

Condition 1

a. No valid steam plant activity radiation monitor alarms or unexplained rise in activity.
b. Containment pressure is less than 3 psig.
c. No valid containment area radiation monitor alarms or unexplained rise in activity.

Condition 2

a. No valid steam plant activity radiation monitor
b. CIAS actuated.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

LOCA- Safety Functions

  1. Containment Temperature and Pressure Control
A

Note:Hydrogen criterion may be omitted until hydrogen monitor is in service
ACCEPTANCE CRITERIA:
Condition 1
a. Containment temperature is less than 235°F.
b. Containment pressure is less than 8.5 psig. c. Hydrogen concentration is less than 1.1%. Condition 2
a. At least one Containment Spray header flow is greater than 4350 gpm.
b. Containment pressure is less than 55 psig. c. Hydrogen concentration is less than 4.9%.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

LOCA- Safety Functions

  1. Maintenance of Vital Auxiliaries
A

a. At least one vital 4.16 kV AC bus energized.
b. At least one of the following trains of PK and PN is energized and is on the same train as the energized vital 4.16 kV AC bus.
• PKA-M41, PKC-M43, and PNA-D25
• PKB-M42, PKD-M44, and PNB-D26
c. No jeopardized safety functions require restoration of electrical power to a vital AC or DC bus.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

LOCA- Safety Functions

  1. Reactivity Control
A

a. Reactor power dropping.
OR
Reactor power less than 2 x 10 lowering. -4% and stable or lowering
b. ALL full strength CEAs are fully inserted. OR
Boration is in progress at greater than 40 gpm.
OR
Adequate shutdown margin as required by Tech Specs is established.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

RX TRIP- Safety Functions

  1. Reactivity Control
A

a. Reactor power dropping
OR
Reactor power is less than 2 x 10-4% and stable or lowering.

b. ALL full strength CEAs are fully inserted. OR
Boration is in progress at greater than 40 gpm.
OR
Adequate shutdown margin as required by Tech Specs is established.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

RX Trip- Safety Functions

  1. Maintenance of Vital Auxiliaries
A

a. At least one vital 4.16 kV AC bus energized.
b. At least one non-vital 13.8 kV AC bus energized.
c. At least one non-vital 4.16 kV AC bus energized.
d. At least one of the following trains of PK and PN is energized and is on the same train as the powered vital 4.16 kV AC bus:
• PKA-M41, PKC-M43, and PNA-D25
• PKB-M42, PKD-M44, and PNB-D26

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

RX Trip- Safety Functions

  1. RCS Inventory Control
A

a. Pressurizer level is 10 - 65%.
b. Pressurizer level is trending to 33 - 53%.
c. The RCS is 24°F or more subcooled.
d. RVLMS indicates 100% RVUH.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Rx Trip- Safety Functions

  1. RCS Pressure Control
A

a. Pressurizer pressure is 1837 - 2285 psia.

b. Pressurizer pressure is trending to 2225 - 2275 psia.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Rx Trip- Safety Functions

  1. Core Heat Removal
A

a. RCS ∆T is less than 10°F.

b. The RCS is 24°F or more subcooled.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Rx Trip- Safety Functions

  1. RCS Heat Removal
A

a. RCS Tc is 560 - 570°F.

b. At least one Steam Generator has level 45 - 60% NR and feedwater is available.
OR
Feedwater is restoring level in at least one Steam Generator to 45 - 60% NR.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Rx Trip- Safety Functions

  1. Containment Isolation
A

a. Containment pressure is less than 2.5 psig.
b. No valid containment area radiation monitor alarms or unexplained rise in activity.
c. No valid steam plant activity radiation monitor alarms or unexplained rise in activity.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Rx Trip- Safety Functions

  1. Containment Temperature and Pressure Control
A

a. Containment temperature is less than 117°F.

b. Containment pressure is less than 2.5 psig.

17
Q

EOP expectations

Placing controllers in manual

A
  1. Do not place systems in manual unless mis-operation in automatic is apparent. Systems placed in manual must be checked frequently to ensure proper operation. This does not apply to systems which are normally placed in manual due to post-trip operating parameters or which are placed in Local-Automatic versus Remote-Automatic. For example, performing a cooldown with SBCS in Local-Automatic or manual is easier and smoother than performing a cooldown using ADVs.
18
Q

LOCA

Harsh containment criteria

A

170 F

Or

10E8 mrem/ hour

The preferred instrumentation for determining harsh containment conditions due to high radiation levels is RU-148 and RU-149 for containment radiation levels.

19
Q

LOCA

Into NC - potential RU monitors

A
  1. RU-2 or RU-3 may be substituted for RU-6 when EW is cross-connected to NC.