EOP Safety Functions Flashcards
LOCA -Safety Functions
RCS Inventory
Condition 1
a. Pressurizer level greater than 10% [15%].
b. RCS is 24°F [44°F] or more subcooled.
c. RVLMS indicates that RVUH level is 16% or more.
Condition 2
a. Safety Injection flow is adequate. REFER TO Appendix 2, Figures.
b. CET Subcooling indicates less than 44°F [60°F] superheat and NOT rising.
c. RCS Subcooling indicates less than 44°F [60°F] superheat and NOT rising.
LOCA-Safety functions
RCS Pressure Control
ACCEPTANCE CRITERIA: Condition 1 a. Pressurizer pressure within the P/T limits. REFER TO Appendix 2, Figures. Condition 2 a. Safety Injection flow is adequate. REFER TO Appendix 2, Figures.
LOCA- SAFETY FUNCTION
- Core Heat Removal
a. CET Subcooling indicates less than 44°F [60°F] superheat and NOT rising.
b. RCS Subcooling indicates less than 44°F [60°F] superheat and NOT rising.
LOCA- Safety Functions
- RCS Heat Removal
a. At least one Steam Generator has level 45 - 60% [45 - 60%] NR.
OR
Feedwater is restoring at least one Steam Generator level to 45 - 60% [45 - 60%] NR.
b. Tc is stable or lowering.
LOCA- Safety Functions
- Containment Isolation
Condition 1
a. No valid steam plant activity radiation monitor alarms or unexplained rise in activity.
b. Containment pressure is less than 3 psig.
c. No valid containment area radiation monitor alarms or unexplained rise in activity.
Condition 2
a. No valid steam plant activity radiation monitor
b. CIAS actuated.
LOCA- Safety Functions
- Containment Temperature and Pressure Control
Note:Hydrogen criterion may be omitted until hydrogen monitor is in service
ACCEPTANCE CRITERIA:
Condition 1
a. Containment temperature is less than 235°F.
b. Containment pressure is less than 8.5 psig. c. Hydrogen concentration is less than 1.1%. Condition 2
a. At least one Containment Spray header flow is greater than 4350 gpm.
b. Containment pressure is less than 55 psig. c. Hydrogen concentration is less than 4.9%.
LOCA- Safety Functions
- Maintenance of Vital Auxiliaries
a. At least one vital 4.16 kV AC bus energized.
b. At least one of the following trains of PK and PN is energized and is on the same train as the energized vital 4.16 kV AC bus.
• PKA-M41, PKC-M43, and PNA-D25
• PKB-M42, PKD-M44, and PNB-D26
c. No jeopardized safety functions require restoration of electrical power to a vital AC or DC bus.
LOCA- Safety Functions
- Reactivity Control
a. Reactor power dropping.
OR
Reactor power less than 2 x 10 lowering. -4% and stable or lowering
b. ALL full strength CEAs are fully inserted. OR
Boration is in progress at greater than 40 gpm.
OR
Adequate shutdown margin as required by Tech Specs is established.
RX TRIP- Safety Functions
- Reactivity Control
a. Reactor power dropping
OR
Reactor power is less than 2 x 10-4% and stable or lowering.
b. ALL full strength CEAs are fully inserted. OR
Boration is in progress at greater than 40 gpm.
OR
Adequate shutdown margin as required by Tech Specs is established.
RX Trip- Safety Functions
- Maintenance of Vital Auxiliaries
a. At least one vital 4.16 kV AC bus energized.
b. At least one non-vital 13.8 kV AC bus energized.
c. At least one non-vital 4.16 kV AC bus energized.
d. At least one of the following trains of PK and PN is energized and is on the same train as the powered vital 4.16 kV AC bus:
• PKA-M41, PKC-M43, and PNA-D25
• PKB-M42, PKD-M44, and PNB-D26
RX Trip- Safety Functions
- RCS Inventory Control
a. Pressurizer level is 10 - 65%.
b. Pressurizer level is trending to 33 - 53%.
c. The RCS is 24°F or more subcooled.
d. RVLMS indicates 100% RVUH.
Rx Trip- Safety Functions
- RCS Pressure Control
a. Pressurizer pressure is 1837 - 2285 psia.
b. Pressurizer pressure is trending to 2225 - 2275 psia.
Rx Trip- Safety Functions
- Core Heat Removal
a. RCS ∆T is less than 10°F.
b. The RCS is 24°F or more subcooled.
Rx Trip- Safety Functions
- RCS Heat Removal
a. RCS Tc is 560 - 570°F.
b. At least one Steam Generator has level 45 - 60% NR and feedwater is available.
OR
Feedwater is restoring level in at least one Steam Generator to 45 - 60% NR.
Rx Trip- Safety Functions
- Containment Isolation
a. Containment pressure is less than 2.5 psig.
b. No valid containment area radiation monitor alarms or unexplained rise in activity.
c. No valid steam plant activity radiation monitor alarms or unexplained rise in activity.