Engineering Flashcards
How many steering units do we have onboard?
4
purpose of list control
keep the flight deck level
location of emergency steering
2nd deck above steering units
What are 4 ways to move the rudders?
helm
trick wheel
jam nut
emergency steering
modes of CHT
in port
at sea
transit
What is the minimum distance from land to discharge CHT?
3 miles
capacity of the CHT tanks
48,000 forward
52,000 aft
How many AC units are there?
10
What type of AC units do we have?
centrifugal
capacity of AC units
363 tons
How many REEFER plants are onboard?
5
type of REEFER plants
reciprocating
capacity of REEFER plants
7 tons
How many cryogenic plants are there?
2
location of cryogenic plants
Hanger Bay 1 portside
Hanger Bay 3 starboardside
primary use of liquid oxygen
breathing air for pilots
primary use of liquid nitrogen
medical
What is the minimum distance from land to discharge plastics?
NEVER
How do we control the trim of the ship?
transfer liquid forward and aft
How much JP5 can we store?
3.5 million gallons
purpose of chill water
cool electronic gear / spaces
location of DC Central
4-119-0-C
of repair lockers
10
of AFFF stations
20
of AFFF reserve tanks
2
location of AFFF reserve tanks
Hanger Bay 1 portside
Hanger Bay 3 starboardside
of Range Guard systems onboard
7
actuating source of Halon
5 lb CO2 bottle
of list control tanks
10
location of list control tanks
5 portside
5 starboardside
4th deck
of list control pumps
2
rate of change in list control
1.5 degrees in 20 min
location of list control
4A shaft alley
How long is the ACPG good for in a contaminated environment?
24 hours or 6 washes in a 140 day period
What is the NFTI used for?
finding trapped personnel and sources of heat
What powers the NFTI?
ten AA batteries
What does the Team Leader do?
directs firefighting efforts and operates the NFTI
types of shoring
H, I, and K
strongest type of shoring
I
What is the max of a piece of shoring?
30x the butt thickness
type of firemain onboard
composite loop
size of the firemain
12 inches
principles of investigation
thoroughly, cautiously, report, repeat
of fire pumps onboard
23
of steam fire pumps
4
What is the numbers of the steam fire pumps?
7, 9, 11, 13
of DECON stations
3
parasitic loads off the firemain
secondary chill water JBD flushing water cooling lube oil CM washdown magazine sprinklers
NFTI
naval firefighting thermal imager
modes of NFTI
chop
pan
location of range guard system
galleys
At what temperature will the fusible link on the range guard melt?
360 degrees
What type of fire is the range guard used on?
deep fat fryer fires
spaces covered by sprinkler systems
magazines
hanger bays
trash rooms
flight deck
location of the distilling plants
2 in each MMR on the upper level
PECU
portable exothermic cutting unit
function of the PECU
cut away damaged steel and make holes in the skin of the ship to assist in the ventilation of a fire
type of steam reboilers onboard
horizontally mounted, shell and u-tube type heat exchangers
location of the reboilers
1A and 4B shaft alleys
CHT
collection, holding and transfer of sewage
What is drained into the CHT tanks?
water closets urinals showers laundry galleys
comminutor
chops, chews up, and grinds fragments into a fluid-like state
location of the O2N2 plants
Hanger Bay 1 portside
Hanger Bay 3 starboardside
types of navy distilling plants
flash
reverse osmosis
vertical basket
purpose of refrigeration plants
maintain the ships food stores
compressor
compresses LP to HP
prime mover
evaporator/cooling coil
copper and aluminum tubing used to cool a space
condenser/heat exchanger
high temp vapor passes through the condenser where it is cooled and condensed by sea water
receiver
temporary storage space for the refrigerant and also as a vapor seal to keep vapor out of the liquid line to the expansion valve
thermal expansion valve
regulates the amount of refrigerant to the evaporator to maintain the temperature of the space being cooled
location of AC plants
1-2 forward AC&R plant
3-4 aft AC&R plant
location of REEFER plants
1-2 forward AC&R plant
3-5 aft AC&R plant
location of #5 AC plant
1 MMR
What is the 21st AFFF mixing station for?
bomb farm
What is AFFF concentrate?
6% AFFF :: 94% water
How are the aircraft elevators raised and lowered?
hydraulic fluid
lifting capacity of the aircraft elevators
130,000 lbs
rate of electric fire pumps
1,000 gpm
rate of steam fire pumps
3,000 gpm
DCWS
damage control watch supervisor
in charge of list control, CHT, etc.
CSC
catapult supervisory control
DCA
damage control assistant
assists the CHENG
RADIAC
radiation detection identification and computation