Emergency Procedures: Flight Engineer Flashcards
1
Q
Engine fire
A
- Select unaffected electrical power source
- Fuel boost pumps switches - OFF
- PTU switches - OFF
- ATM pump switches - OFF
2
Q
APU fire with a minimum of one engine generator operating
A
- Pull applicable APU fire pull handle
2. Push applicable agent discharge button
3
Q
APU fire, engine generator not operating, and external power connected
A
- EXT PWR switch - ON
- Pull applicable APU fire pull handle
- Push applicable agent discharge button
4
Q
APU fire, engine generator not operating, and external power not connected
A
- Place APU GEN SELECT switch to unaffected APU, if applicable otherwise proceed to step 3
- APU GEN switch - ON
- Pull applicable APU fire pull handle
- Push applicable agent discharge button
5
Q
Wing fire
A
- Notify pilot of affected zone
- FSS ARM/panel safe switch - ARM
- Press appropriate zone alarm push button
6
Q
Excessive fluid leak - engine running
A
- Select unaffected electrical power source
- Fuel boost pump switches - OFF
- PTU switches - OFF
- ATM pump switches - OFF
- Electric suction boost pump switches - OFF
- Depress hydraulic engine pump switches for affected engine
7
Q
Wheel well, underfloor or PTU area fire with engine(s) and APU(s) operating
A
- Notify pilot of affected zone
- FSS ARM/panel safe switch - arm
- Press appropriate zone alarm push button