Emergency Procedures Flashcards
The apparatus air outlet can fill ___ lengths of hose in approximately ___ seconds and each length of 2 1/2” hose filled with air can keep approximately ___ people afloat.
2 lengths of hose, approximately 20 seconds, 10 people per length of 2 1/2” hose. EP Water rescue 1 add 1 sec 3.3 & 4.2
If the surfboard is used it must be tethered.
Emergency Procedures Water Rescue 3 sec 4.2
When does the Altair Digital Gas Meter alarm?
- When the atmosphere reaches 10% of the LEL
- Oxygen enriched atmosphere (23.5%)
- Oxygen deficient atmosphere (19.5%)
EP Natural gas add 2 sec 2.5
How long does it take for the Altair Natural Gas Meter to run through a self-check?
40 seconds EP Natural Gas add 2 sec 2.2
While monitoring the air the Altair Natural Gas Meter will emit a vibrating pulse and a flashing LED green light every ___ seconds.
30 seconds EP Natural Gas add 2 sec 2.3
A series of crosses under the COMB/EX icon on the Altair meter indicates the atmosphere is above ___% LEL.
100% This is an extremely dangerous atmosphere as it is indicative of a potentially explosive environment that members should not operate in except for life saving purposes. EP Natural Gas add 2 sec 4.1
The indoor action level for natural gas emergency operations is ___%
The outdoor action level for natural gas emergency operations is ___%
Indoor 10% LEL
Outdoor 20% LEL
EP Natural Gas add 2 sec 4.1
A series of three crosses along the screen under the O2 icon indicates the atmosphere is above ___% oxygen.
25% oxygen EP natural gas add 2 sec 5.3
What is the normal oxygen level reading on the Altair?
20.8% EP natural gas add 2 sec 5.3