Emergency Equipment Flashcards
What is the number and location of portable Fire Extinguishers?
2: Secured behind copilot’s seat and right rearmost cabin seat.
What is the location of the First Aid Kit?
Aft cabinet across from toilet
Where is the Water Barrier Stored?
Secured to bulkhead behind pilot seat
What type operation requires the Water Barrier to be installed?
Single pilot operations with no passengers
What is the location of the Life Vests?
Under each pilot and passenger seat
Where is the Life Raft stored?
Aft cabinet across from the toilet
What is the rated capacity for the life raft?
10
What is the location of the Smoke Goggles?
In a compartment in the ledge adjacent to each pilot seat
What is the cockpit indication that the ELT is transmitting?
Flashing red light on the cockpit ELT panel
Reference the source for required oxygen quantity for dispatch.
POH Vol 1, Section 6
Reference the source for action required during takeoff and landing at airports with elevation between 8,300’ and 14,0000’.
AFM Supplement 2
Is oxygen available to any occupants (pilot or passenger) with the Oxygen Handle in the Pulled position?
No
Under what conditions do the passenger masks deploy with the OXYGEN SUPPLY CONTROL knob in the PAX AUTO position?
Cabin pressure exceeds 14,700’ + or - 300’, provided the supply handle is pushed in
What is the purpose of the CREW ONLY position of the OXYGEN SUPPLY CONTROL knob?
Disables automatic deployment of passenger oxygen masks
What action occurs when the OXYGEN SUPPLY CONTROL knob is moved to the PAX OVRD position?
Causes manual deployment of passenger oxygen masks, provided the supply handle is pushed in
What is indicated by the yellow star in the flow indicator next to the oxygen mask compartment?
Oxygen is flowing through the mask
What air flows to the pilot oxygen mask with the Auto Dilution Valve in the Pulled (open) position?
Cabin Air only
What air flows to the pilot oxygen mask with the Auto Dilution Valve in the Pushed (closed) position?
Oxygen supply metered according to the position of the mask Regulator knob
When does the oxygen mask Auto Dilution Valve automatically move to the Pushed position?
Cabin Altitude between 8,300’ and 10,000’ (B/E Aerospace masks)
Cabin Altitude between 6,500’ and 9,500’ (Eros masks)
What pilot action is required regarding the mask Auto Dilution Valve in the event of smoke, fire, fumes?
The valve must be manually closed
What oxygen is supplied to crew with the mask Regulator Knob in the following positions?
EMER: Pure oxygen, under positive pressure
100%: Pure oxygen, under demand
NORM: Oxygen diluted according to cabin altitude, under demand. 100% above 35,000 Cabin Altitude
What is the volume of the oxygen cylinder?
50 ft3