Emergency Core Cooling Flashcards
Where do the High Pressure Safety Injection Pumps discharge to?
All 4 Cold Legs
What is the shutoff head of the HPSI Pump?
1800 psia
Where do the LPSI Pumps discharge to?
Their respected Cold legs
What is the shutoff head of the LPSI pump?
200 psia
What component in the Emergency Core Cooling System is considered passive?
Safety Injection Tanks
At which pressure do the SITs start supplying borated water?
600 psia
What kind of water is the Refueling Water Tank?
Borated water
What is the purpose of the Recirculation Sumps?
Provide back up inventory to the HPSI and CS Pumps when RWT level is 9.4%
What happens on a Recirculation Actuation Signal?
LPSI Trips
Mini Circulation Paths Close
RAS Sumps- CS pumps- SDCHx-Containment Spray Nozzles
What is the purpose of the Trisodium Phosphate Baskets?
Increase pH and ensure Iodine remains in solution
What is the purpose of the Containment Spray System?
Spray borated water at a High High Containment Pressure
Reduce Containment Pressure
Remove Iodine from atmosphere
What is the purpose of the Shutdown Cooling System?
Cool down the reactor from 350 degrees to refueling temperature
Which pumps are used in the Shutdown Cooling System?
LPSI and CS Pumps
What cools the Shutdown Cooling Heat Exchanger?
Essential Cooling Water System
What is the flow path of the Shutdown Cooling System?
hot leg – pumps – SDCHx – cold leg