Fuel Panel Switches - Larger ones are ____ smaller ones are ______
Fuel Panel Switches - Larger ones are AC smaller ones are DC
Power to the boost pumps is supplied from the MAIN AC BUS ___ for Pump ___ and ____ and from the MAIN AC BUS ___ for Pump ____ and ____.
Power to the boost pumps is supplied from the MAIN AC BUS A for Pump No.1 and No.3 and from the MAIN AC BUS B for Pump No.2 and No.4
Function of External power monitor relay:
Prevents power with improper phase, voltage or frequency to power the AC
Power source to MAIN AC BUS A and B are assured by:
Transfer Relay system
If you lose MON DC, you lose START DC…. to regain START DC, what can you do?
Select any engine on the starter or the emergency inverter.
If the Run around relay circuitry fails, the FLT ESS AC bus is powered by what:
Main AC BUS A
During APU GEN Only the following is automatically de-energized above 8K’
a. No.1A Hydraulic pump.
b. Empennage de-ice system.
c. Circuit de-energized by the load monitor control relay
When the yellow GEN light is illuminated on the horizontal panel
Indicates a primary gen drive bearing failure, aux bearing in use
The nose gear up and locked switch when up and lock will disable:
GOB and cabin warning horn.
If you lose main AC BUS B you lose which boost pumps and which hyd pumps
Boost pumps 2-4
1A and 2 hyd pumps
GEN 4 off light:
Indicates that the GEN is unable to power any bus
STBY ATT Indicator is powered by:
Flight ESS DC
If APU gen is the only one, how is the flt ess AC bus powered:
APU GEN trhough RAR relays.
What activates load shedding:
selecting prop or emp de-ice
Gen 4 and APU are the only available gens, which provides power
Gen 4 is the only power
TRUs are de-energized by
Pulling the CB
If Main AC A fails, MON AC bus is powered by any gen through_______
RAR relays
The Supp panel does not provide:
Overfrequency protection
Battery V & AmpH
24 volts, 31 amph
Gen 3 off light illuminates means:
Not powering bus B
The emergency inverter powers: what
TIT indicators (START ESS AC)
Purpose of load monitor circuit
Prevent exceeding load capacity of a single gen in flight
Ground air sensing circuit disables:
Jettison circuit on the ground
If TR1 and TR3 fails
Lose noting (1 and 2 à loose main and ext main DC)