Electrics Flashcards
Battery Discharge (BAT DISCHARGE) Light
Illuminated (amber) – with BAT switch ON, excessive battery discharge detected
TR UNIT Light
Illuminated (amber) –
• on the ground – any TR has failed.
• in flight –• TR1 failed; or
• TR2 and TR3 failed
Electrical (ELEC) Light
Illuminated (amber) – a fault exists in DC power system or standby power system.
Note: Operates only with airplane on ground
STANDBY Power Off (PWR OFF) Light
Illuminated (amber) – one or more of the following busses are unpowered:
• AC standby bus
• DC standby bus
•battery bus
Generator Drive (DRIVE) Lights
Illuminated (amber).
Integrated drive generator (IDG) low oil pressure caused by one of the following:
• IDG failure
• engine shutdown
• IDG automatic disconnect due to high oil temperature
• IDG disconnected through generator drive DISCONNECT switch
STANDBY POWER Switch
AUTO (guarded position) -
In flight, or on the ground, and AC transfer busses powered:
• AC standby bus is powered by AC transfer bus 1
• DC standby bus is powered by TRI, TR2 and TR3
In flight, or on the ground, loss of all AC power
• AC standby bus is powered by battery through static inverter
• DC standby bus is powered by battery
• Battery bus is powered by battery.
STANDBY POWER SWITCH
OFF (center position) -
• STANDBY PWR OFF light illuminates
• AC standby bus, static inverter, and DC standby bus are not powered.
STANDBY POWER Switch
BAT (unguarded position) -
• AC standby bus is powered by battery through static inverter
• DC standby bus and battery bus are powered directly by battery
TRANSFER BUS OFF Lights
Illuminated (amber) -
Related transfer bus is not powered.
SOURCE OFF LightsIlluminated (amber) –
No source has been manually selected to power the related transfer bus, or the manually selected source has been disconnected.
• if a source has been selected to power the opposite transfer bus, both transfer busses are powered
Generator Off Bus (GEN OFF BUS) LightsIlluminated (blue) –
IDG is not supplying power to the related transfer bus
Generator (GEN) Switches
Three position switch, spring–loaded to neutral.
OFF – disconnects IDG from related AC transfer bus by opening generator circuit breaker.
ON – connects IDG to related AC transfer bus by disconnecting previous power source and closing generator circuit breaker
BUS TRANSFER Switch - AUTO (guarded position)
BTBs operate automatically to maintain power to AC transfer busses from any operating generator or external power.
• DC cross tie relay automatically provides normal or isolated operation as required.
BUS TRANSFER Switch - OFF
isolates AC transfer bus 1 from AC transfer bus 2 if one IDG is supplying power to both AC transfer busses.
• DC cross tie relay opens to isolate DC bus 1 from DC bus 2.
• Inhibits TR3 input from connecting to AC transfer bus 1
APU Generator Off Bus (GEN OFF BUS) Light
Illuminated (blue) – APU is running and not powering a bus