Electrical System: Load Manager Flashcards
After the battery voltage drops to a preselected setting (______), the engine throttle will be increased to compensate for the low voltage and electrical system loads.
approximately 12.8 volts
The fast idle output will remain ON for a minimum of ____ and until ____ is achieved.
10 minutes / 13.0 VDC
An alarm sounds if a low-voltage condition (____) develops.
below 11.9 volts
If the low-voltage condition continues (for ___), then the shedding of electrical loads will begin.
approximately 1 minute
A shed point is the voltage that will cause a load to be ____ if the system voltage drops to this point.
turned off
An unshed point is the voltage that must be achieved before a load is ___ on once it has been shed.
turned back
A shed system (load) will not be recognized for ____ or until the unshed voltage setting is maintained for____.
5 minutes / 1 minute.
The fast idle system will be maintained for a minimum of ___ and until a voltage reading of ___ is achieved, even if any system shedding did not occur.
10 minutes / 13.0
AC shed/unshed voltage
12.00 volts / 12.20 volts
Passenger Flood shed/unshed voltage
11.8 volts / 12.00 volts
Driver Flood shed/unshed voltage
11.40 volts / 11.60 volts
Roof Lights shed/unshed voltage
11.00 volts / 11.40 volts
It is important to note that at minimum, when ALL electrical accessories are turned on and engine is running at idle (____), the alternator will be unable to keep up with the electrical demands placed on it thereby causing the air conditioning to be turned off.
500-750 rpm
At idle with ALL electrical accessories ON, system voltage can drop well below ____.
12.0 Volts
Even with the engine high idle engaged with all electrical accessories βONβ, system voltage will vary between ____.
12.9 to 13.1 Volts.