After the battery voltage drops to a preselected setting (____), the engine throttle will be increased to compensate for the low voltage and electrical system loads.
approximately 12.8 volts
The fast idle output will remain ON for a minimum of ___ and until ___ is achieved.
10 minutes / 13.0 VDC
An alarm sounds if a low-voltage condition (___) develops.
below 11.9 volts
If the low-voltage condition continues (for ___), then the shedding of electrical loads will begin.
approximately 1 minute
A shed system (load) will not be recognized for____ or until the unshed voltage setting is maintained for ___
5 minutes / 1 minute.
AC shed/unshed
12.00 / 12.20
Passenger flood shed/ unshed
11.80 / 12.00
Driver flood shed/unshed
11.40 / 11.60
Roof light shed/ unshed
11.00 / 11.40