Describe the main generator.
Starter/Generator.
28V/300 amps.
Shaft driven by the AGB.
Describe Generator 2.
115 A
Belt driven by AGB.
What does generator 2 power during normal operations?
Gen 2 Bus
What does the main generator power during normal operations?
Gen 1 Bus
Describe the batteries.
Either 1 or 2.
Lead Acid.
24V, 42 amp hour.
How long will batteries supply power by themselves?
20 minutes–loads of less than 60 A.
30 minutes–loads less than 50 A.
Can the DC system be powered by a GPU?
Yes.
What amps are required of a GPU for systems and for start?
500 amps for systems.
1000 amps for start.
What electrical system protection is in place for usage of a GPU?
External power control unit will disconnect power if voltage goes above 29.5 V or below 23 V.
How many volts is the electrical system?
28 volts
Name the items on the hot battery bus.
Clock Cockpit dome light 50% Cargo door motor Cargo door light Standby bus
Where are the batteries housed?
Aft Fuselage
What does the Standby Bus power?
Audio Panel
VHF NAV/COMM 1
GPS 1
Avionics Blower
What is the Battery Bus powered by?
GEN 1 normal ops.
Battery when GEN 1 is offline.
What powers the Generator 1 Bus?
GEN 1 during normal ops.
What powers the Generator 2 Bus?
GEN 2 during normal ops.
What powers the Non-Essential Bus?
GEN 1 during normal ops.
What powers Avionics 1 Bus?
GEN 1 during normal ops.
What powers Avionics 2 Bus?
GEN 1 during normal ops.
What does the Bus Tie Interlock do?
Allows either generator to charge the battery or power systems in the event of a single generator failure.
CAWS “GEN 2 OFF” describe what happens?
GEN 2 has failed.
GEN 2 Tie closes and GEN 1 supplies all bus bars.
CAWS “GEN 1 OFF” describe what happens?
GEN 1 has failed.
GEN 2 Tie closes and GEN 2 supplies all bus bars.
CAWS “ESNTL BUS” means?
BAT 1, GEN 1, or GEN 2 is below 22V.
CAWS “AV BUS” means?
Either Avionics Bus is below 22V.
CAWS “BAT OFF” means?
Battery is offline.
CAWS “BATTERY” means?
Battery Overvoltage or Overcurrent.
CAWS “BUS TIE” means?
Bus Tie is open.
CAWS “INVERTER” means?
Inverter below 20V.
If GEN 1 or GEN 2 exceed limits what warning do you get?
CAWS “EIS CAUTION”
How many inverters are there?
Two 26 VAC 400 Hz static inverters.
What are the ratings on the emergency battery?
24V, 5Ah Lead Acid.
When does the EPS Emergency Power System Activate?
Battery Bus failure or total power loss.
What does the EPS power?
COMM/NAV 1
Standby Attitude Indicator
Lighting circuits of CDI and Standby Attitude Indicator
What powers Inverter 1?
GEN 1
What powers Inverter 2?
Battery Bus
Bus 2 Tie is normally?
Closed.
If Bus 2 tie opens how old you know?
CAWS BUS TIE would illuminate.
GEN 2 tie is normally?
Open when GEN2 is online.