Electrical Flashcards
P6 panel location? How many
On right sidewall behind FO
4 panels
P7 panel location?
Aft of the overhead panel
AC system powered by? AC pwr with engines running?
2 APU generators and/ or 2 ext pwr receptacles.
4 IDG’s
How are AC buses powered while on the ground?
By ext pwr and APU generators through the synchronous bus
Cannot be paralleled
“AVAIL” lights indicate
Voltage and frequency of the respective pwr source are within limits
IDG’s lubricated and cooled by……
Self-contained oil system
Each IDG has a gen control sw and gen drive disconnect sw
T or F?
True
ELEC DRIVE 3 ( or 1,2,3,4)
Either low oil psi, or high oil temp, or GCB open due to uncorrectable gen freq fault in respective IDG.
Purpose of Synchronous bus?
Interconnects the 4 AC busses and allows the 4 IDG’s to work in parallel.
Split system breaker (ssb)
Separates synchronous bus into left and right half and allows each half to be powered by different APU or external power sources.
Ground handling bus powers?
Fueling sys Lower cargo handling equipment Lower cargo compartment lights Aux hyd pump 4 Flight deck access lights
Ground service bus powered when?
Powered by AC bus 1 on the gnd and in flight
Gnd handling bus can be powered on Flt and gnd?
False, gnd only
Gnd handling bus powers….
Lwr cargo handling equipment
Lower cargo doors
Aux hyd pump 4
Lwr cargo compartment lights
Fuel equipment
Gnd handling bus automatically when?
Ext pwr one is AVAIL
If not available, APU GEN 1 will power if AVAIL