EICAS Flashcards
Power for EICAS CRTs:
-Can come from the batteries and is limited to 5 minutes without AC power for cooling
-Can come from the batteries and is limited to 5 minutes without packs running for cooling
-Comes from the AC essential bus and is limited to 5 minutes operation without DC power for cooling
-Is DC and has no restrictions
Can come from the batteries and is limited to 5 minutes without AC power for cooling
Pushing the MASTER WARNING switchlight also silences the aural warnings except for:
Flap clacker, trim clacker, AP disconnect cavalry charge, landing gear warning horn.
Stall warbler, GPWS/TCAS, triple chime, overspeed clacker
Configuration warnings, overspeed clacker, triple chime, stall warbler
All of the above
Flap clacker, trim clacker, AP disconnect cavalry charge, landing gear warning horn.
Stall warbler, GPWS/TCAS, triple chime, overspeed clacker
Configuration warnings, overspeed clacker, triple chime, stall warbler
Choose the correct statement:
Warning messages can be removed from view by pressing the CAS button on the ECP
Warning messages always are accompanied by a triple or single clime
Warning messages cannot be removed from view unless the applicable failure has been rectified
Caution messages can be removed by pressing the CAS button on the ECP provided that one main generator is operating and online.
Warning messages cannot be removed from view unless the applicable failure has been rectified
Caution messages will always appear as a ____ message on the CAS.
white
amber
red
green
amber
If the ED1 CRT display should fail:
ED1 will automatically be transferred to copilot’s MFD position
ED1 data is not displayed until a new display for ED1 is selected on the Source Select panel
ED1 will automatically be transferred to ED2
ED1 can only be displayed by using the STEP button and ED2display
ED1 will automatically be transferred to ED2
The four levels of CAS messages in order of importance are:
warning, caution, advisory, status
caution, warning, status, advisory
warning, caution, status, advisory
caution, warning, advisory, status
Warning, caution, advisory, status
Which warnings are not disabled by placing both DCU Switch lights to DISABLE?
TCAS
triple chime
cavalry charge
EGPWS
TCAS
EGPWS
What four buttons on the ECP are manual and thus will still operate if the ECP fails?
PRI
STAT
MENU
CAS
ECS
STEP
PRI
STAT
CAS
STEP
After engine start, when both engines are stabilized and the oil pressures are normal, EICAS logic replaces the analog oil pressure gauges with:
N1 fan vibration gauges
N2 turbine vibration gauges
fuel temperature gauges
oil temperature gauges
N1 fan vibration gauges