What is EA Credit 1 called?
Optimize Energy Performance
How many points are available for Optimize Energy Performance?
Ten
What is the intent of Optimize Energy Performance Credit?
Achieve increasing levels of energy performance.
What standard is used as a baseline for Optimize Energy Performance Credit?
ASHRAE/IESNA Standard 90.1-1999
What metric is used when evaluating Optimize Energy Performance Credit?
Cost
What method is used to determine cost savings in Optimize Energy Performance Credit?
Energy Cost Budget Method (whole building simulation).
What are the regulated energy components for Optimize Energy Performance Credit?
HVAC systems, building envelope, service hot water systems, and interior lighting.
How much must you reduce energy design cost for a new and existing buildings to get two points for the Optimize Energy Performance Credit 1.1?
20% for new, 10% for existing.
How much must you reduce energy design cost for a new and existing buildings to get all ten points for the Optimize Energy Performance Credit 1.1?
60% for new, 50% for existing.
What is the EA Credit 2 called?
Renewable Energy
What is the intent of Renewable Energy Credit?
Encourage and recognize increasing levels of on-site renewable energy,help to reduce environmental impacts associated with fossil fuel energy use.
How many points are available for Renewable Energy?
Three
What is the requirement for Renewable Energy Credit 2.1?
5% of total energy load cost in renewables.
What is the requirement for Renewable Energy Credit 2.2?
10% of total energy load cost in renewables.
What is the requirement for Renewable Energy Credit 2.3?
20% of total energy load cost in renewables.
What are some renewable technologies to achieve EA Credit 2?
Solar, wind, geothermal, biomass, hydro and bio-gas.
What is EA Credit 3 called?
Additional Commissioning
What is the intent of Additional Commissioning Credit?
Ensure entire building designed, constructed, and calibrated to operate as intended.
What is the difference between Prerequisite 1 and Credit 3?
Prerequisite 1 is for “fundamental building”, Credit 3 is for “entire building.”
How many points are available for Additional Commissioning?
One
What is the 1st requirement of Additional Commissioning Credit?
1) A commissioning authority, independent of the design team, shall review design prior to the construction document phase.
What is the 2nd requirement of Additional Commissioning Credit?
2) An independent commissioning
authority shall review construction documents when close to completion.
What is the 3rd requirement of Additional Commissioning Credit?
3) An independent commissioning authority shall review the contractor submittals relative tosystems being commissioned.
What is the 4th requirement of Additional Commissioning Credit?
4) provide the owner with a single manual that contains the information required for recommissioning building systems.
What is the 5th requirement of Additional Commissioning Credit?
5) Have a contract in place to review building operation with O&M staff,including a plan for resolution of outstanding commissioning-related issues within one year after construction completion date.
What is EA Credit 4 called?
Ozone Protection
What are 2 intents of the Ozone Protection Credit?
Reduce ozone depletion and support compliance with the Montreal Protocol.
How many points are available for Ozone Protection?
One
What is required for the Ozone Protection Credit?
Install base building level HVAC, refrigeration equipment, and fire suppression systems that do not contain HCFC’s or Halons.
What are some strategies to achieve the Ozone Protection Credit?
Building reuse: replace building systems that contain HCFCs or Halons; new buildings: specify refrigeration and fire suppression systems that use no HCFCs or Halons.
What is EA Credit 5 called?
Measurement & Verification
What is the intent of Measurement & Verification Credit?
Accountability and optimization of building energy and water consumption.
How many points are available for Measurement & Verification?
One
What is the framework used for Measurement & Verification?
Option B,C or D of the2001 International Performance Measurement & Verification Protocol (IPMVP) Volume I: Concepts and Options for Determining Energy and Water Savings.
What energy & water systems are included in the Measurement & Verification Credit?
Lighting systems & controls, constant and variable motor loads, variable frequency drive operation, chiller efficiency at variable loads, cooling load, air and water economizer, air distribution static pressures,boiler, indoor water risers, outdoor irrigation.
What are some strategies to achieve the Measurement & Verification Credit?
Model energy & water to predict savings. Design with equipment that measure energy & water
What is EA Credit 6 called?
Green Power
What is the intent of the Green Power Credit?
Encourage the development and use of grid-source energy technologies on a net zero pollution basis
How many points are available for the Green Power?
One
What is the requirement for the Green Power Credit?
Engage in two-year contract to purchase power generated from renewable sources for at least 50% of power.
What framework does the Green Power credit use?
Center for Resource Solutions (CRS) Green-e products certification requirements.
What can Green Power be derived from?
Solar, wind, geothermal, biomass, or low impact hydro sources.
Prereq. Memory 3 flying building systems commissioners were minding energy performance, while cfc’s escaped from the HVAC system.
3 prerequisites, Fundamental Building Systems Commissioning, Minimum Energy Performance, CFC Reduction in HVAC&R Equipment .
Credits (6 oem pa loompas, re,act,oddly when they measure and verify green power)
6 credits, Optimize Energy Performance, Renewable Energy, Additional commissioning, ozone depletion, measurement and verification, green power.
Point Structure (Tent the 3 wives and the 4 little ones)
10,3,1,1,1,1