Ductless Air-Conditioning Systems Flashcards
The refrigerant evaporating temperature range of most comfort cooling systems is ____.
40 F - 50 F
As moisture in a window air conditioner system evaporates, it helps to cool the ____.
compressor and condenser
In a room air conditioner, the thermostat’s sensing bulb is usually installed at the inlet of the ____.
evaporator
PSC (permanent split capacitor) compressor motors have difficulty starting if the supplied voltage is low. To overcome this problem, a technician will often install a ____.
relay and start capacitor
The most common installation location of a PTAC is ____.
in an exterior wall of a building
The method by which a PTHP changes between modes of operation (heating and cooling) is that ____.
a reversing valve changes the direction of refrigerant flow
All types of PTACs use ____ compressors.
hermetic
PTACs are normally charged with ____
R-134a or R-140A
Console units typically us a(n) ____ metering device.
TXV