DSC Air conditioning - Press - Vent Flashcards
What compose the air conditioning system ?
- two pack control valves
- two packs
- one mixing unit
What is the purpose of the mixing unit ?
mix air from the cabin and the air coming from the packs
What is the purpose of the trim air valve and the hot air ?
optimize the temperature by adding hot air tapped upstream of the packs
What is the purpose of the pack flow control valve ?
It is controlled by the ACSC and regulate the air flow
When will the pack flow control valve close ?
- pack overheat
- low pressure
- fire PB
- engine start
What is the purpose of the emergency RAM air ?
provide ambient air to the mixing unit.
Can be use to remove smoke and in case of dual pack failure
When will the emergency ram air inlet open ?
- when PB pressed and
- delta P is less than 1PSI and
- Outflow valve in automatic control mode (will open at 50%)
How does the ACSC control the temperature of the pack ?
It adjust the temp by modulating bypass valve and the ram air inlet flap.
When will the pack flow automatically adjust ?
- single pack
- use of APU bleed
- normal flow if in LO and temp cannot be satisfied
What compose the ACSC ? and how will it work in case of failures ?
Composed of two lanes per ACSC
Single lane failure => no effect the other takes over
Both lanes failure => pack lost, hot air valve close and associated trim air valve close
What compose the cabin press system ?
- two CPC
- one residual pressure control unit
- one outflow valve with an actuator with 3 motors
- one control panel
- two safety valves
In normal cabin press operation what control the system ?
Only one CPC at a time, the other is on standby
When will the transfer between CPC happen ?
failure
70sec after landing
Can be forced by selecting Mode sel to MAN for 10sec or more and back to auto
What is the normal cabin pressure limit ?
8000ft
How is the outflow valve operated and by what ?
3 differents motors
- two for automatic mode associated with their CPC
- one for manual mode
In manual mode the N°1 CPC backup section signal the position to ECAM