Drager X-am 2500 Flashcards
How long is the drager sensor warm up period
5 minutes
To operate the back light
press the +M button for 3 seconds, it will backlight for 10 seconds
What battery does the drager use
nickel hydride
The drager does not charge on the x-dock station
true
what does blinking red light in dock indicate
charging
what does solid red light indicate
fully charged (takes about 4 hours)
What gases are used to callibrate the drager
methane and pentane
If the Drager fails a bump test
removed and repeat test, then call haztech if it fails again
02 sensor A1/A2
A1= 19.5
A2= 23.5%
LEL sensor A1/A2
A1= 10%
A2= 20%
CO sensor A1/A2
A1= 25 ppm
A2= 50 ppm
H2S sensor A1/A2
A1= 10 ppm
A2= 15 ppm
To silence A1 alarm
press OKon once
A2 alarms
signal IDLH and to evacuate immediately
- It cannot be acknowledged
An X symbol in the top right of the display indicates an error
Press OKon for 3 seconds and a error code will be displayed, dealing with error codes is beyond the scope of 472 operations