Drager PSS 7000 Flashcards
What is the standard duration of an SDBA set?
31 minutes @ 50 Litres/minute
What does STOPCAB stand for?
Self contained Two stage Open circuit Positive pressure Compressed Air Breathing Apparatus set
First Stage Reducer takes pressure from ___ bar to ___ bar
First Stage Reducer takes pressure from 300 bar to 6-9 bar
High Pressure Hose = ___ bar
Medium Pressure Hose = ___ bar
Second Person Connection = ___ bar
High Pressure Hose = 300 bar
Medium Pressure Hose = 6-9 bar
Second Person Connection = 6-9 bar
At what pressure is the Time of Warning (TOW) triggered?
84 bar
What does TOW stand for?
Time of Warning
What does ADSU stand for?
Automatic Distress Signal Unit
At what point will the ADSU operate?
If no movement is detected for 30 seconds, pre-alarm emitted for 15 seconds
At what pressure does the Pneumatic low pressure warning whistle actuate?
74 bar (+/- 5 bar)
Solid green battery LED = ?
Fully Charged
Single flash green LED = ?
Charging
Double flash green LED = ?
Battery Temperature Fault
What does DPFM stand for?
Duel purpose face mask
What does EMU stand for?
Electronic Monitoring Unit