Drafting Flashcards

1
Q

Hard sleeve should be submerged at least ______ if possible to prevent formation, of a whirlpool which might permit air to enter the pump

A

18 inches

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

If not possible to submerge hard sleeve 18” whirlpools can be prevented by placing a ________ at the water surface

A

Baffle

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Baffles can be improvised from:

A

Salvage covers, wooden doors, or similar objects

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Hard sleeve connections should be hammered tight with rubber mallet to

A

Prevent Leak

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Strainer should be kept off bottom to prevent grit and abrasive material from entering the pump to ____ ______

A

Prevent block

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

6” Blind cap should only be _______ _______

A

Hand tight

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Transfer Valve should be placed in _______ _________ when priming

A

Volume Position

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Before priming the pump, all unused gates and valves shall be _______, and _______ _____ shall be placed on unused discharge gates

A

Closed, Blind Caps

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Hydrant static pressure shall always be determined before opening the discharge gate

A

Because it tells operator necessary info to determine what the drop in hydrant pressure is when the line is supplied

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

When operating the priming pump increase engine pressure to ________ to assist the __________ ______ on the system

A

1300 RPM, Electrical Load

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

The priming time should not exceed __________. If the pump is not primed in this time, stop and look for ______ _____

A

45 seconds, Air Leaks

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

The following points should be checked upon failure to get water from draft:

A
  • Operation done in proper order
  • Gaskets in hard sleeve sand connections tight
  • Recheck all valves for proper position check gates for leakage
  • Whether there is oil in tank for priming pump
  • Strainer submerged, but not resting on bottom
  • Strainers are clear of foreign matter
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

When changing the position of the transfer valve on all pumps, the pump pressure shall be reduced to _______ when operating from draft, and to a_____ difference between intake and discharge pressure, when operating from a hydrant, two pump operation, or relay

A

50psi, 50psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Where there is a doubt as to the best position of the transfer valve

A

Check it by delivering the desired amount of water at the required pressure, not the engine speed on the tachometer, change to the other position, adjust to the desired pressure , and note whether the engine speed is lower or higher . The pump shall be operated with the transfer valve in the position which develops the desired pressure at the lower engine speed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

The transfer valve shall be placed in the pressure position of supplying under

A

500 GPM

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Hard sleeve connections should be hammered tight with rubber mallet to

A

Prevent Leak

17
Q

Strainer should be kept off bottom to prevent grit and abrasive material from entering the pump to ____ ______

A

Prevent block

18
Q

6” Blind cap should only be _______ _______

A

Hand tight

19
Q

Transfer Valve should be placed in _______ _________ when priming

A

Volume Position

20
Q

Before priming the pump, all unused gates and valves shall be _______, and _______ _____ shall be placed on unused discharge gates

A

Closed, Blind Caps

21
Q

Hydrant static pressure shall always be determined before opening the discharge gate

A

Because it tells operator necessary info to determine what the drop in hydrant pressure is when the line is supplied

22
Q

When operating the priming pump increase engine pressure to ________ to assist the __________ ______ on the system

A

1300 RPM, Electrical Load

23
Q

The priming time should not exceed __________. If the pump is not primed in this time, stop and look for ______ _____

A

45 seconds, Air Leaks

24
Q

The following points should be checked upon failure to get water from draft:

A
  • Operation done in proper order
  • Gaskets in hard sleeve sand connections tight
  • Recheck all valves for proper position check gates for leakage
  • Whether there is oil in tank for priming pump
  • Strainer submerged, but not resting on bottom
  • Strainers are clear of foreign matter
25
Q

When changing the position of the transfer valve on all pumps, the pump pressure shall be reduced to _______ when operating from draft, and to a_____ difference between intake and discharge pressure, when operating from a hydrant, two pump operation, or relay

A

50psi, 50psi

26
Q

Where there is a doubt as to the best position of the transfer valve

A

Check it by delivering the desired amount of water at the required pressure, not the engine speed on the tachometer, change to the other position, adjust to the desired pressure , and note whether the engine speed is lower or higher . The pump shall be operated with the transfer valve in the position which develops the desired pressure at the lower engine speed

27
Q

The transfer valve shall be placed in the pressure position of supplying under

A

500 GPM