Dosimetric Concepts 1 Flashcards
Beam quality
The penetrating power of the beam
Higher beam energy has higher penetrating ability
Monoenergetic beams
Electrons and gamma rays
12MeV
Heterogeneous beams
X-ray
4MV, 18MV
Effective energy
Type of X-ray beam is always heterogeneous in RT, but X-ray can have an equivalent energy of a mono energetic that have equivalent HVL
Can be estimated as 1/3 the max electron potential
4MeV/3=1.33 MeV effective energy
Supervoltage
50-150kVp
HVL 1-8 mm Al
Treatment distance 15-30cm
90%dose at 5mm depth
Ortho
150-500 kVp
HVL 1-4 mm Cu
59-70cm SSD
90% dose at 2xm depth
Primary radiation
That which passes directly from the source through the collimating system and to the point of measurement/patient
Secondary radiation
Patient scatter
Collimator scatter
Leakage radiation